Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

interface loopback

Configure a Loopback interface.

Syntax interface loopback number

To remove a loopback interface, use the no interface loopback number command.

Parameters
number Enter a number as the interface number. The range is from 0 to 16383.
Defaults Not configured.
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the M I/O Aggregator.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Example
Dell(conf)#interface loopback 1655
                                             Dell(conf-if-lo-1655)#
                                          
Related Commands

interface — configures a physical interface.

interface null — configures a Null interface.