Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

power-cycle stack-unit

To hard reset any stack unit including master unit.

Syntax power-cycle stack-unit unit-number
Parameter
Unit number The unit number ranges from 0 to 5.
Defaults None
Command Modes EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6.(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Usage Information

This command is supported on the M I/O, FN410S, and FN410T Aggregators.

This command is used to reset the stack-unit. The master unit can also be power cycled using this command.