ASR0000

Message
The watchdog timer expired.
Detailed Description
The operating system or potentially an application failed to communicate to the baseboard management controller (BMC) within the timeout period.
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0001

Message
The watchdog timer reset the system.
Detailed Description
The operating system or an application failed to communicate to the baseboard management controller (BMC) within the timeout period. The system was reset per the configured setting.
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0002

Message
The watchdog timer powered off the system.
Detailed Description
The operating system or an application failed to communicate to the baseboard management controller (BMC). The system powered off per the configured setting.
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0003

Message
The watchdog timer power cycled the system.
Detailed Description
The operating system or an application failed to communicate to the baseboard management controller (BMC). The system powered cycled per the configured setting.
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0008

Message
The watchdog timer interrupt was initiated.
Detailed Description
The operating system or an application failed to communicate to the baseboard management controller (BMC) within the timeout period. The BMC invoked a system interrupt. (IPMI sensor type code 23h - offset 00h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0009

Message
The system returned from a watchdog timer event.
Detailed Description
The system is communicating to the baseboard management controller (BMC).
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0100

Message
The BIOS watchdog timer reset the system.
Detailed Description
The operating system or an application failed to communicate to the system board within the timeout period. The system was reset per the configured setting. (IPMI sensor type code 23h offset 01h event 3:0 - 2h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0101

Message
The OS watchdog timer reset the system.
Detailed Description
The operating system or an application failed to communicate within the timeout period. System was reset. (IPMI sensor type code 23h offset 01 - event 3:0 - 3h if booting 4h if running)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0102

Message
The OS watchdog timer shutdown the system.
Detailed Description
The operating system or an application failed to communicate within the timeout period. The system was shutdown. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0103

Message
The OS watchdog timer powered down the system.
Detailed Description
The operating system or an application failed to communicate within the timeout period. The system was powered down. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0104

Message
The OS watchdog timer powered cycle the system.
Detailed Description
The operating system or an application failed to communicate within the timeout period. The system was powered cycled. (IPMI sensor 23h offset - 03h event 3:0 - 4h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0105

Message
The OS watchdog timer powered off the system.
Detailed Description
The operating system or an application failed to failed to communicate within the timeout period. The system was powered off. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0106

Message
The OS watchdog timer expired.
Detailed Description
The operating system or an application failed to communicate within the timeout period. No action was taken. (IPMI sensor type code 23h - offset 00h event 3:0 - 4h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0107

Message
The OS watchdog timer pre-timeout interrupt was initiated.
Detailed Description
The operating system or an application failed to respond to a pre-notification with-in the timeout period. (IPMI sensor type code 11h - offset 07h)
Recommended Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
2233
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR0108

Message
The system returned from an OS watchdog timer event.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

ASR200

Message
The watchdog timer expired at arg1 .
Arguments
  • arg1 = day month date hh:mm:ss yyyy
Detailed Description
The watchdog timer has expired at the date and time identified in the message, because iDRAC did not receive a response within the specified time.
Recommended Response Action
To determine the correct cause of the exception, contact your service provider
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5006
Server Administrator Trap ID
5006

ASR201

Message
The watchdog timer restarted the system at arg1 .
Arguments
  • arg1 = day month date hh:mm:ss yyyy
Detailed Description
The watchdog timer has restarted the system at the date and time identified in the message, because the operating system has crashed or hung.
Recommended Response Action
To determine the correct cause of the exception, contact your service provider
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5006
Server Administrator Trap ID
Not Applicable

ASR202

Message
The watchdog timer turned off the system at arg1 .
Arguments
  • arg1 = day month date hh:mm:ss yyyy
Detailed Description
The watchdog timer has turned off the system after the specified time at the date and time identified in the message, because the operating system has crashed or hung.
Recommended Response Action
To determine the correct cause of the exception, contact your service provider
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5006
Server Administrator Trap ID
Not Applicable

ASR203

Message
The watchdog timer performed an AC power cycle on the system at arg1 .
Arguments
  • arg1 = day month date hh:mm:ss yyyy
Detailed Description
The watchdog timer has performed an AC power cycle on the system after the specified time at the date and time identified in the message, because the operating system has crashed or hung.
Recommended Response Action
To determine the correct cause of the exception, contact your service provider
Category
System Health
Subcategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5006
Server Administrator Trap ID
Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\