Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.0

PDF

STOR Event Messages

STOR003

Message
Missing parameter.
Detailed Description
Required parameter is missing.
Recommended Response Action
Refer to the RAID profile to determine required parameters.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR004

Message
Invalid parameter value.
Detailed Description
Provided parameter value is not valid.
Recommended Response Action
Refer to the RAID profile to determine the valid parameters values.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR006

Message
Unable to complete the operation.
Detailed Description
The operation could not be completed because of an issue with the management controller (either the iDRAC or the Chassis Management Controller (CMC)) that is managing the storage.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR007

Message
Unable to allocate resources.
Detailed Description
The operation could not be completed because of insufficient memory space on the management controller (either the iDRAC or the Chassis Management Controller (CMC)) managing the storage.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR009

Message
Physical disk FQDD did not identify a valid physical disk for the operation.
Detailed Description
Physical disk did not identify valid physical disk for the operation.
Recommended Response Action
Provide compatible physical disk with the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR010

Message
RAID level not supported on controller.
Detailed Description
The operation cannot be completed because the RAID level entered is not supported by the controller.
Recommended Response Action
Enter a valid RAID level and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0101

Message
No RAID controller is displayed.
Detailed Description
No RAID controller data to display. The system is powered off, no RAID controller is present in the system, or the RAID controller is not connected to the system.
Recommended Response Action
Check if the server has power, RAID controller is available, and that a RAID controller is connected to the system.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0102

Message
No batteries are displayed.
Detailed Description
No battery data to display. The system is powered off, batteries are not present on the system, batteries are not connected to the RAID controller, or the batteries are depleted.
Recommended Response Action
Check if the server has power, batteries are available, and batteries are connected to the RAID controller.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0103

Message
No physical disks are displayed.
Detailed Description
No physical disk data to display. The system is powered off, physical disks are not present on the system, or physical disks are not connected to the enclosure or backplane
Recommended Response Action
Check if the server has power, physical disks are available, and physical disks are connected to the enclosure or backplane.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0104

Message
No virtual disks are displayed.
Detailed Description
No virtual disk data to display. The system is powered off, physical disks are not present on the system, or virtual disks are not created.
Recommended Response Action
Check if the server has power, physical disks are available, and virtual disks are created.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0105

Message
No enclosures are displayed.
Detailed Description
No enclosure data to display. The system is powered off, enclosures are not present on the system, or enclosures are not connected to the RAID controllers.
Recommended Response Action
Check if the server has power, enclosures are available, and enclosures are connected to the RAID controllers.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0106

Message
Fans are not connected to enclosures or data about fans is unavailable.
Detailed Description
No fan data to display. The system is powered off, no fan enclosures are present in the system, or the fans are not connected to the enclosures.
Recommended Response Action
Check if the server has power, enclosure fan is available, and fan is connected to the enclosure.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0107

Message
EMMs are not connected to enclosures or data about EMMs is unavailable.
Detailed Description
No EMMs data to display. The system is powered off, no enclosure EMMs are present, or the EMMs are not connected to the enclosures.
Recommended Response Action
Check if the server has power, EMMs are available, and EMMs are connected to the enclosure.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0108

Message
Temperature probes are not connected to enclosures or data about temperature is unavailable.
Detailed Description
No temperature data to display. The system is powered off, no enclosure temperature probes are present in the system, or the temperature probes are not connected to the enclosures.
Recommended Response Action
Check if the server has power, enclosure temperature probe is available, and temperature probe is connected to the enclosure.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0109

Message
Power supply unit is not connected to the enclosure or data about power supply unit is unavailable.
Detailed Description
No power supply unit data to display. The system is powered off, no power supply unit is present in the system, or the power supply unit is not connected to the enclosure.
Recommended Response Action
Check if the server has power, enclosure power supply unit is available, and power supply unit is connected to the enclosure.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR011

Message
Stripe size not supported on controller.
Detailed Description
The operation cannot be completed because the stripe size entered is not supported by the controller.
Recommended Response Action
Enter a valid stripe size and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0110

Message
Invalid Fully Qualified Device Descriptor (FQDD).
Detailed Description
The specified Fully Qualified Device Descriptor (FQDDs) system component name is invalid.
Recommended Response Action
Verify that the correct Fully Qualified Device Descriptor (FQDD) system component name is specified. See the help text (The help text for the raid subcommand can be obtained by running "racadm help raid") or documentation for valid FQDD system component names.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0111

Message
Invalid reference key.
Detailed Description
The specified reference key is invalid.
Recommended Response Action
Verify that the correct reference key is specified. See the help text or documentation for valid reference keys.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR012

Message
Provided Physical disk not valid for this operation.
Detailed Description
One or more of the specified physical disks cannot be used for the operation requested. Physical disk protocol and media type, along with other physical disk characteristics like Secure Encryption and T10 protection, need to match the requirements of the requested operation.
Recommended Response Action
Make sure the specified physical disk has the appropriate protocol and media type for the requested operation. Specify a different physical disk with a state appropriate for the requested operation and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR013

Message
One or more storage device(s) are not in a state where the operation can be completed.
Detailed Description
One or more storage device(s) are in a state that prevents the operation from completing.
Recommended Response Action
Make sure the specified storage devices are in a state appropriate for the requested operation and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR015

Message
Maximum virtual disks allowed for this controller has been reached.
Detailed Description
A new virtual disk cannot be created because the maximum number of virtual disks are already created.
Recommended Response Action
A new virtual disk cannot be created until one is deleted.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR016

Message
The physical disk specified is not large enough to be a hot spare for this virtual disk.
Detailed Description
The physical disk drive cannot be assigned as the hot-spare of this virtual disk because the capacity of the physical disk is not sufficient.
Recommended Response Action
Specify a physical disk with a larger capacity or replace the specified physical disk with one with more capacity, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR017

Message
The specified Virtual Disk is not valid for the operation.
Detailed Description
The virtual disk specified is not compatible with the requested operation or a specified operation parameter is not appropriate for the virtual disk type specified.
Recommended Response Action
Make sure the operation parameters are appropriate for the virtual disk type. Specify a compatible virtual disk for the requested operation and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR018

Message
No foreign drives detected.
Detailed Description
This operation did not detect any foreign drives. This may be because no foreign drives are present or the only foreign drives are in a secured state.
Recommended Response Action
If the only foreign drives present are in a secured state, run a secure erase operation on the drives and retry the operation. Otherwise the operation was not successful because there are no foreign drives.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR019

Message
The specified passphrase is not valid.
Detailed Description
The passphrase specified does not follow the passphrase character criteria of the controller character.
Recommended Response Action
Enter a passphrase that meets the passphrase character criteria of the controller, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR020

Message
A controller key is already present.
Detailed Description
The controller key cannot be set because a key is already present.
Recommended Response Action
Delete the current key and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0200

Message
Array Manager is installed on the system.
Detailed Description
Installing Storage Services and Array Manager on the same system is not a supported configuration. Storage Services is not installed on a system where Array Manager is installed.
Recommended Response Action
Uninstall either Storage Services or Array Manager and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2135
Server Administrator Trap ID
10300

STOR0201

Message
Unable to determine whether the system has the minimum required versions of the RAID controller drivers and firmware.
Detailed Description
Unable to determine whether the system has the minimum required versions of the RAID controller drivers.
Recommended Response Action
See the Readme file on the installation media for driver and firmware requirements. If Storage Services experiences performance problems, make sure that minimum supported versions of the drivers and firmware are installed. For a list of correct driver and firmware versions, contact the service provider.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2164
Server Administrator Trap ID
10100

STOR0202

Message
The configuration file (Path: arg1 ) that contains firmware and driver information for arg2 is not updated or is incorrectly formatted to complete the comparison.
Arguments
  • arg1 = file path
  • arg2 = controller name
Detailed Description
Storage Services is unable to determine whether the system has the minimum required versions of the RAID controller firmware and drivers because a configuration file is not readable, corrupted, or has missing data.
Recommended Response Action
Reinstall Server Administrator and Storage Services.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2166
Server Administrator Trap ID
75300

STOR0203

Message
The current operating system kernel version and the non-RAID SCSI driver version are older than the minimum required versions.
Detailed Description
The version of the operating system kernel and the driver do not meet the minimum requirements. Storage Services may not be able to display or perform storage management functions until the system meets the minimum requirements.
Recommended Response Action
See the Readme file on the installation media for operating system kernel and driver version requirements. Update the system to meet the minimum requirements and then reinstall Storage Services.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2167
Server Administrator Trap ID
10300

STOR0204

Message
The non-RAID SCSI driver version is older than the minimum required version.
Detailed Description
The driver version does not meet the minimum requirements and Storage Services cannot perform the required operations until the minimum requirements are met.
Recommended Response Action
See the Readme file for the driver requirements and update the system to meet the minimum requirements and reinstall Storage Services.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2168
Server Administrator Trap ID
10300

STOR0205

Message
Global rescan initiated for all storage components in the system.
Detailed Description
A rescan of all storage components in the system is initiated.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2261
Server Administrator Trap ID
75100

STOR0206

Message
Smart thermal shutdown feature is enabled.
Detailed Description
The storage shutdown feature based on high ambient temperature (smart themal shutdown) is enabled.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2262
Server Administrator Trap ID
10100

STOR0207

Message
Smart thermal shutdown feature is disabled.
Detailed Description
The storage shutdown feature based on high ambient temperature (smart themal shutdown) is disabled.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2263
Server Administrator Trap ID
10100

STOR0208

Message
Protection policy has changed.
Detailed Description
A new protection policy is created or an existing protection policy is modified.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2287
Server Administrator Trap ID
10100

STOR0209

Message
Unable to monitor or manage SAS components because the initialization sequence of the devices did not complete.
Detailed Description
The initialization sequence of SAS components did not complete during system startup.
Recommended Response Action
Do the following: 1) Make sure that the supported versions of the SAS drivers and firmware are installed. 2) Reboot the system. If problem persists, reinstall Server Administrator and Storage Services on the managed node to make sure all the required components are installed.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2314
Server Administrator Trap ID
10400

STOR021

Message
The controller key is not present.
Detailed Description
The virtual disk cannot be secured because a controller key is not present.
Recommended Response Action
Set an appropriate controller key and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0210

Message
SCSI sense data ( arg1 ) received from arg2 .
Arguments
  • arg1 = sense info
  • arg2 = device name
Detailed Description
A SCSI device may have experienced an error that generated sense data after the device recovery.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2095
Server Administrator Trap ID
75100;85100;90100

STOR0211

Message
The arg1 has returned to normal state.
Arguments
  • arg1 = device name
Detailed Description
The device identified in the message that was previously in an error state has returned to a normal state. For example, if an enclosure became too hot and subsequently cooled down, or if a degraded virtual disk returns to normal state.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2121
Server Administrator Trap ID
75200;80200;85200;90200;95200;100200;105200;110200;115200;120100

STOR0212

Message
The arg1 has failed.
Arguments
  • arg1 = device name
Detailed Description
The device (physical disk or an enclosure) identified in the message has failed. The device (physical disk or an enclosure) failure was detected while performing a rescan. However, physical disk failures are also detected during a check consistency operation.
Recommended Response Action
Replace the identified device. A failed device is inidicated with a red color "X" status icon. Perform a rescan after replacing the failed device.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
2048
Server Administrator Trap ID
75400;80400;85400;90400;95400;100400;105400;110400;115400;120400

STOR022

Message
The controller is not security capable.
Detailed Description
The specified controller does not have the capability to secure virtual disks.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR023

Message
Unable to perform configuration operations because a configuration job for the device already exists.
Detailed Description
Unable to perform configuration operations because a configuration job for the device already exists.
Recommended Response Action
Wait for the current job for the device to complete or cancel the current job before attempting more configuration operations on the device.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR024

Message
Unable to create a configuration job because a configuration job for the device already exists.
Detailed Description
Configuration changes for the specified device are already scheduled.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR025

Message
Unable to delete any pending configuration because the configuration job is already scheduled.
Detailed Description
The pending configuration cannot be deleted because the configuration job is already scheduled.
Recommended Response Action
Delete the current configuration job for the device to stop pending configuration changes.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR026

Message
A configuration job was not created because there are no pending configuration changes.
Detailed Description
A configuration job was not created because there are no pending configuration changes.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR027

Message
Virtual Disk name is not supported.
Detailed Description
Setting the Virtual disk name is not a valid operation on the specified controller.
Recommended Response Action
Do not specify the virtual disk name and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR028

Message
Virtual disk not found.
Detailed Description
The requested operation cannot be completed because the specified virtual disk is not found.
Recommended Response Action
Provide a valid virtual disk FQDD (Fully Qualified Device Descriptor) and retry the operation..
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR029

Message
Physical disk not found.
Detailed Description
The requested operation cannot be completed because the specified physical disk is not found.
Recommended Response Action
Provide a valid physical disk FQDD (Fully Qualified Device Descriptor) and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR030

Message
Controller not found.
Detailed Description
The requested operation cannot be completed because the specified controller is not found.
Recommended Response Action
Provide a valid controller FQDD (Fully Qualified Device Descriptor) and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR031

Message
Lifecycle Controller is not enabled.
Detailed Description
For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation. Lifecycle Controller has been disabled by pressing F2 Setup, selecting iDRAC Configuration, and selecting Lifecycle Controller Settings on boot up or through a remote operation.
Recommended Response Action
For 11G systems: Use the iDRAC configuration utility to enable the System Services by pressing on the CTRL+E option on boot up at the targeted system. For 12G systems: Use F2 Setup, select iDRAC Configuration, and select Lifecycle Controller Settings, to enable the Lifecycle Controller on boot up of the targeted system.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR032

Message
Lifecycle Controller is currently in use.
Detailed Description
Lifecycle Controller is unable to gain access to internal storage because it is in use by another application or operation.
Recommended Response Action
Wait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not currently in Lifecycle Controller Configuration utility 2) Not waiting for user intervention at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR033

Message
Invalid parameter value for Start/Until Time.
Detailed Description
The requested operation cannot be completed because an invalid value is specified for Start/Until Time.
Recommended Response Action
Enter a valid Start/Until Time and retry the operation. For more information about the Start/Until Time, see the RAID Profile specification.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR034

Message
Invalid parameter value for RebootJobType.
Detailed Description
The requested operation cannot be completed because an invalid value is specified for RebootJobType.
Recommended Response Action
Enter a valid RebootJobType value and retry the operation. For more information about the RebootJobType parameter, see the RAID Profile specification.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR035

Message
Unable to perform operation because either the number of storage objects specified is insufficient or the storage objects are not in a required state to perform this operation.
Detailed Description
Unable to perform operation because either the number of storage objects specified is insufficient or the storage objects are not in a required state to perform this operation.
Recommended Response Action
Check the number and state of storage objects and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR037

Message
Missing required parameter arg1 .
Arguments
  • arg1 = parameter name
Detailed Description
Unable to complete the requested operation because one or more input parameters identified in the message are not specified.
Recommended Response Action
Enter all the required parameters and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR038

Message
Invalid parameter value for arg1 .
Arguments
  • arg1 = parameter name
Detailed Description
Unable to complete the requested operation because one or more input parameters identified in the message are not valid.
Recommended Response Action
Specify a valid value for identified parameter.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR039

Message
Mismatch in AttributeName and AttributeValue count.
Detailed Description
Unable to complete the requested operation because of a mismatch in the number of AttributeName and AttributeValue values specified.
Recommended Response Action
Specify a valid number of AttributeName and AttributeValue pair values and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR040

Message
Invalid AttributeName arg1 .
Arguments
  • arg1 = attribute name
Detailed Description
Unable to complete the requested operation because an invalid AttributeName value is specified.
Recommended Response Action
Specify a valid AttributeName value for the attribute identified in the message and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR041

Message
Invalid value for AttributeName arg1
Arguments
  • arg1 = attribute name
Detailed Description
Unable to complete the requested operation because an invalid value for the attribute identified in the message is specified.
Recommended Response Action
Specify a valid value for the attribute identified in the message and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR042

Message
Unsupported value for AttributeName arg1
Arguments
  • arg1 = attribute name
Detailed Description
Unable to complete the requested operation because the attribute value specified is not supported in the current configuration.
Recommended Response Action
Specify a value for the attribute identified in the message by using one of the possible values currently available for that attribute.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR043

Message
One or more selected physical disk drives are part of virtual disk that is not Secondary RAID Level 0.
Detailed Description
One or more physical disk drives selected for the operation are part of a virtual disk that is not Secondary RAID Level 0.
Recommended Response Action
This operation is not supported unless the previous virtual disk on the selected physical disk drives are deleted first. To perform the operation, delete any virtual disk on the selected physical disks drives and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR044

Message
All physical disks specified are not part of the same disk group.
Detailed Description
One or more physical disks specified to create virtual disk (VD) is not valid because it is not part of the same disk group.
Recommended Response Action
Enumerate existing virtual disks to find the physical disks of the same disk group. Specify physical disks that are of the same disk group and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR045

Message
StartingLBA and Size parameters are required to create a virtual disk.
Detailed Description
The specified physical disks have fragmented disk space, therefore StartingLBA and Size parameters are required to be specified in order to create a virtual disk.
Recommended Response Action
Specify StartingLBA and Size parameters and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR046

Message
The specified StartingLBA and Size values combination result in an overlapping virtual disk.
Detailed Description
Unable to complete the create virtual disk operation because the StartingLBA and Size value combination results in an overlapping virtual disk.
Recommended Response Action
Refer to the users guide to provide the correct StartingLBA and Size combination values.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR047

Message
Unable to change the value of attribute arg1 because it is ReadOnly.
Arguments
  • arg1 = attribute
Detailed Description
Unable to change the value of the attribute identified in the message because it is ReadOnly.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR048

Message
Controller is not Dell Key Management capable.
Detailed Description
Either the controller or the firmware on the controller does not support the Dell Key Management feature.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR049

Message
Controller is in Local Key Management mode.
Detailed Description
The controller is in Local Key Management mode.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR050

Message
Controller is in Dell Key Management mode.
Detailed Description
The controller is in Local Key Management mode.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0501

Message
Unable to configure RAID.
Detailed Description
Unable to create a virtual disk due to unknown reasons.
Recommended Response Action
Do one of the following and retry the operation: 1) Exit the RAID Configuration wizard. 2) Update the RAID controller firmware to the latest version. 3) Reboot the system and press the <F10> key to re-enter Lifecycle Controller, and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0502

Message
Unable to launch RAID Configuration wizard.
Detailed Description
No RAID controller is installed on the system.
Recommended Response Action
Install the RAID controller and do the following: 1) Reboot the system. 2) Press the <F10> key to re-enter Lifecycle Controller. 3) Retry RAID configuration.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0503

Message
Successfully erased RAID configuration.
Detailed Description
Existing RAID configuration was successfully erased.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0504

Message
Successfully completed RAID operation.
Detailed Description
The RAID operation was successful.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0505

Message
Unable to delete virtual disks.
Detailed Description
Unable to delete the existing virtual disks for unknown reasons.
Recommended Response Action
Exit the RAID Configuration wizard and retry the operation. If the problem persists do the following: 1) Reboot the system. 2) Press the <F10> key to re-enter Lifecycle Controller. 3) Retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0506

Message
Unable to create virtual disk.
Detailed Description
The physical disk is unreadable or the RAID controller is not responding.
Recommended Response Action
Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, replace the physical disk or update the RAID controller firmware to the latest version, and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0507

Message
Insufficient physical disk space on selected RAID controller.
Detailed Description
The RAID controller does not have sufficient number of initialized physical disks or adequate disk space to create the requested virtual disk.
Recommended Response Action
Connect additional physical disks to the RAID controller, initialize the physical disks, and retry the operation. To initialize the physical disks, reboot the system and select Option ROM during system startup.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0508

Message
No supported controllers present for RAID configuration.
Detailed Description
Unable to configure RAID as the supported RAID controller is not present.
Recommended Response Action
Install a supported RAID controller and the required number of physical disks for the RAID configuration, and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0509

Message
No RAID levels are supported.
Detailed Description
The controller does not have the minimum number of initialized disks to create a virtual disk.
Recommended Response Action
Connect required number of initialized physical disks to the RAID controller and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR051

Message
StartingLBA and Size value combination is greater than allowed by the physical disk size.
Detailed Description
The requested operation cannot be completed because the specified StartingLBA and Size value combination is greater than allowed by the physical disk size.
Recommended Response Action
Specify the Size value only and allow the instrumentation to calculate the StartingLBA value then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0510

Message
Encryption configuration failed.
Detailed Description
Unable to apply the RAID controller encryption because RAID controller is not reponding.
Recommended Response Action
Retry the operation. If the problem persists, reboot the system or update the RAID controller firmware to the latest version and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0511

Message
Unable to change the encryption key.
Detailed Description
Unable to change the encryption key due to an internal error.
Recommended Response Action
Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0512

Message
Unable to apply the encryption key.
Detailed Description
Unable to apply the encryption key due to an internal error.
Recommended Response Action
Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0513

Message
Unable to encrypt virtual disks.
Detailed Description
Unable to encrypt unsecure virtual disks due to an internal error.
Recommended Response Action
Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0514

Message
Unable to initialize the selected physical disk drive(s).
Detailed Description
The physical disk drive(s) cannot be initialized because the selected RAID controller does not support this operation while in non-RAID mode.
Recommended Response Action
Do one of the following: 1) Select a controller that is in RAID mode and retry the operation. 2) Update the controller firmware to the latest version and retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR052

Message
Attempt to exceed the number of supported of virtual disks on a controller or disk group.
Detailed Description
The maximum limit on the number of virtual disks that can be created on the specified controller or disk group has been reached.
Recommended Response Action
Refer to the specific controller users guide for information on the number of supported virtual disks allowed.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR053

Message
The controller key is not present. The key must be retrieved from the Dell Key Management Server.
Detailed Description
The system could not obtain a controller key from the Dell Key Management Server.
Recommended Response Action
For more information about obtaining a key, see Dell Key Manager or Lifecycle Controller Remote Services Guide availalbe at dell.com/support/manuals.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR054

Message
Controller is not CacheCade capable.
Detailed Description
The controller or the firmware on the controller does not support the CacheCade feature.
Recommended Response Action
Refer to the specific controller users guide for more information.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR058

Message
This operation is not supported on this device.
Detailed Description
The operation is not supported on the target device.
Recommended Response Action
For more information, see Lifecycle Controller-Remote Services documentation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR059

Message
The requested operation is not currently valid because there are no virtual disks on the controller.
Detailed Description
The requested operation cannot be completed because there are no virtual disks (VD) available on the specified controller.
Recommended Response Action
Create a virtual disk and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR060

Message
Configuration operations are not supported on the specified storage controller.
Detailed Description
The requested operation is not supported on the specified storage controller.
Recommended Response Action
For more information about supported operations, see the documentation specific for the targeted storage controller.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR061

Message
Initializing virtual disk is not supported on the RAID controller.
Detailed Description
The initializing virtual disk operation is not supported on the target device.
Recommended Response Action
For more information about supported operations, see the documentation specific for the targeted RAID controller or the Lifecycle Controller Remote Services Quick Start Guide.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR062

Message
One or more physical disks specified are full and cannot be used to create additional virtual disks.
Detailed Description
One or more physical disks specified are full and cannot be used to create additional virtual disks.
Recommended Response Action
Make sure all physical disks specified to create a virtual disk have the required amount of free space and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR063

Message
Unable to assign the specified virtual disk to multiple Virtual Adapters in single assignment mode.
Detailed Description
In order to prevent data loss, the system has prevented the assignment of a Virtual Disk to multiple Virtual Adapters because the clustered assignment mode is not enabled.
Recommended Response Action
Enable clustered assignment mode or unassign the virtual disk from the Virtual Adapter it is currently assigned to and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR064

Message
One or more physical disks specified for creating a virtual disk do not have the same block size.
Detailed Description
Unable to create the requested virtual disk because the physical disks specified did not have the same block size.
Recommended Response Action
Verify that the physical disks selected for creating the virtual disk have the same block size and retry the operation. The block size can be determined by reviewing the physical disk inventory and checking the BlockSize property for each physical disk.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR065

Message
One or more physical disks specified for creating a virtual disk are not T10 Protection Information capable.
Detailed Description
Unable to create the requested virtual disk because one or more specified physical disk(s) is not T10 Protection Information capable.
Recommended Response Action
Verify that the physical disks selected for creating a virtual disk are T10 Protection Information capable, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR066

Message
Controller is not T10 Protection Information capable.
Detailed Description
The requested operation did not succeed because the selected RAID controller is not T10 Protection Information capable.
Recommended Response Action
Verify that the RAID controller selected for the operation is T10 Protection Information capable, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR067

Message
Controller does not support uneven span RAID10 virtual disks.
Detailed Description
The operation did not succeed since the selected controller does not support creating uneven span RAID10 virtual disks.
Recommended Response Action
The selected controller is not capable of creating an uneven span RAID10 virtual disk. Specify the proper span length and span depth combination for creating RAID10 virtual disk on the selected controller, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR068

Message
Unable to perform the requested RAID configuration because the Lifecycle Controller version on the server does not have the necessary capabilities.
Detailed Description
The requested RAID configuration operation did not succeed because the Lifecycle Controller version on the target server does not have the necessary capabilities.
Recommended Response Action
Check the Lifecycle Controller version on the target server and update it with the latest version available.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR069

Message
Unable to run the arg1 method, because the number of elements entered for VDPropNameArry and VDPropValueArray is unequal.
Arguments
  • arg1 = method name
Detailed Description
The method name identified in the message could not be successfully completed, because the number of elements entered for VDPropNameArry and VDPropValueArray is not equal.
Recommended Response Action
Enter equal number of elements (pair value), and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR070

Message
Unable to run the WS-MAN method arg1 , because an invalid parameter arg2 is entered.
Arguments
  • arg1 = method name
  • arg2 = parameter name
Detailed Description
The method name identified in the message could not be successfully completed, because the number of elements entered for VDPropNameArry and VDPropValueArray is not equal.
Recommended Response Action
Enter a valid parameter, and then retry the operation. For more information about a valid parameter, refer to the SimpleRAIDProfile document available at Dell Tech Center http://en.community.dell.com/techcenter/extras/m/white_papers/20263535.aspx
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0701

Message
Storage objects are unavailable in the current system configuration.
Detailed Description
There are no RAID controllers, physical disks or virtual disks discovered by instrumentation that can be configured.
Recommended Response Action
Storage objects are unavailable in the current system configuration. Make sure that the storage devices are installed in the system, and then retry the operation after the Collect System Inventory On Restart (CSIOR) feature has updated the system inventory. If the issue persists, contact your service provider.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR0702

Message
The value entered for the arg1 option is invalid
Arguments
  • arg1 = option name
Detailed Description
The value entered for the option name identified in the message is invalid.
Recommended Response Action
For more information, run the RACADM command "racadm raid help createvd".
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR071

Message
The specified Span Count is not valid for creating a RAID 10. Valid Span Counts are: arg1
Arguments
  • arg1 = valid span counts
Detailed Description
The configuration operation could not be performed because the specified span count is not valid.
Recommended Response Action
Enter a valid span count, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR072

Message
iDRAC Service Module (ISM) is either not present or not running on the server OS.
Detailed Description
The configuration operation could not be performed because it requires iDRAC Service Module (ISM) service to be present and running in the server Operating System.
Recommended Response Action
Make sure the iDRAC Servive Module (ISM) service is running on the server Operating System and then retry the operation. Refer to the iDRAC User Guide for installing and starting ISM.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR073

Message
The iDRAC Service Module version present on the server OS does not support the requested PCIe SSD (NVMe) device operation.
Detailed Description
The iDRAC Service Module version present on the server OS does not support the requested PCIe SSD (NVMe) device operation.
Recommended Response Action
Update the Dell iDRAC Service Module (ISM) to the version that supports the requested operation on the PCIe SSD (NVMe) device.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR074

Message
The requested RAID configuration operation is not allowed because the controller is currently in Non-RAID mode.
Detailed Description
The requested RAID configuration operation will not be allowed because the RAID controller is currently in Non-RAID mode.
Recommended Response Action
In order to perform a RAID configuration operation, change the controller mode to RAID and retry the operation. For switching to RAID mode using the F2 System Setup utility, go to Device Settings > "RAID Controller "> Controller Management > Advanced Controller Management > Switch to RAID mode.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR075

Message
The operation cannot be performed because the enclosure configuration mode (Split or Unified) change request is pending.
Detailed Description
The requested operation could not be completed because there is an operation pending to change the enclosure configuration mode (Split or Unified). This operation is exclusive because it involves changing the RAID backplane topology.
Recommended Response Action
Do one of the following: 1) Create a job to complete the pending enclosure mode change request operation, allow the job to complete, restart the server, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR076

Message
Enclosure configuration mode (Split/Unified) cannot be changed because there are already pending operations.
Detailed Description
The requested operation could not be completed because at least one other pending operation was found on the RAID controller. This operation needs exclusivity because it involves changing RAID backplane topology.
Recommended Response Action
Do one of the following: 1) Create a job to complete the pending operations, allow the job to complete, and then retry the operation. 2) Cancel any pending operations on the RAID controller, and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR077

Message
Unable to change Patrol Read State since Patrol Read Mode is not set to Manual.
Detailed Description
A Patrol Read State change operation cannot be performed if the Patrol Read Mode is not set to Manual.
Recommended Response Action
Change the Patrol Read Mode to Manual before performing a Patrol Read State change operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR078

Message
The requested operation requires a reboot type that does not match the reboot type required for pending operations.
Detailed Description
The requested operation cannot be performed because it involves server reboot type which is different than the reboot type of pending operations. Combining operations with different reboot types for the same RAID controller is not supported by iDRAC.
Recommended Response Action
Cancel any pending operations on the RAID controller and then retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR079

Message
The device does not support this operation or is in a state that does not allow this operation.
Detailed Description
The requested operation cannot be performed because it is either not supported by the device or the device was not in the right state to perform the operation.
Recommended Response Action
Make sure the device supports the requested operation. If the operation is supported, then make sure the server is turned on and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR081

Message
The job could not be created because the reboot type selected for the job creation and the reboot type required for pending operations do not match.
Detailed Description
The job could not be created because the reboot type selected for the job creation and the reboot type required for pending operations do not match.
Recommended Response Action
Change the reboot type for job creation and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR082

Message
The operation cannot be stopped or cancelled because the operation is not currently running.
Detailed Description
The operation cannot be stopped or canceled because the operation is not currently running.
Recommended Response Action
Make sure the operation is running before attempting to cancel or stop the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR083

Message
The Physical Disk(s) specified are too small to create a Virtual Disk of the requested size.
Detailed Description
The Physical Disk(s) specified are too small to create a Virtual Disk of the requested size.
Recommended Response Action
Specify Phsyical Disk FQDD IDs of physical disk drive(s) that have a larger disk space, and retry the operation.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR084

Message
Unable to create the job because another job is currently running
Detailed Description
The requested job cannot be run because another job is currently running. Two options for running jobs on multiple storage controllers are: 1) Run the jobs on each controller individually. Wait for each job to complete before starting the configuration and job creation on the next controller. 2) Schedule multiple jobs to run at a later time using the scheduling options.
Recommended Response Action
Make sure that the currently running job is completed, and then retry the operation. If necessary, recreate the configuration and the job. For information about running jobs on multiple storage controllers, see the iDRAC Online Help or iDRAC Users Guide.
Category
Configuration
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR089

Message
The storage configuration operation is successfully completed and the change is in pending state.
Detailed Description
The storage configuration operation is successfully completed and the change is in pending state.
Recommended Response Action
To apply the configuration operation immediately, create a configuration job using the --realtime option. To create the necessary real-time job, run the jobqueue command. For more information about jobqueue command, run the racadm help jobqueue command.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR090

Message
Unable to create a virtual disk because an invalid value of span count value is entered for the RAID level selected.
Detailed Description
Unable to create a virtual disk because an invalid value of span count value is entered for the RAID level selected.
Recommended Response Action
Enter a span count value (-sc option) that is appropriate for the RAID level selected. See the PERC Controller Users Guide for valid span count values. Retry the operation by running the RACADM storage createvd command with the appropriate options.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR092

Message
Unable to run the configuration operation on the controller because foreign configuration import operation is in progress.
Detailed Description
The requested configuration operation cannot be run because a foreign configuration import operation on the controller is already in progress.
Recommended Response Action
Wait for the import process to complete before running any configuration operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR093

Message
Unable to run the configuration operation because the controller is not available for the import process.
Detailed Description
The configuration operation cannot be performed because the controller is not available for import process.
Recommended Response Action
Make sure an operation is not pending on the controller. If an operation is pending, wait for the operation to complete or cancel the pending operation and then rety the operation. Refer to the storage controller documentation for compatibility information.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR094

Message
The storage configuration operation is successfully completed and the change is in pending state.
Detailed Description
The storage configuration operation is successfully completed and the change is in pending state.
Recommended Response Action
To apply the configuration operation immediately, create a configuration job using the --realTime option. To apply the configuration after restarting the server, create a configuration job using the -r option.To create the necessary real-time and restart jobs, run the jobqueue command. For more information about jobqueue command, run the racadm help jobqueue command.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR095

Message
Storage operation is successfully completed.
Detailed Description
Storage operation is successfully completed.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR096

Message
Unable to create a virtual disk because the disk space size value entered for the virtual disk is less than the lower limit value (100 MB).
Detailed Description
A virtual disk cannot be created because the disk space size value entered for the virtual disk is less than the lower limit value (100 MB).
Recommended Response Action
Enter a value (the -size option) equal or higher than 100 MB, and then retry the operation.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR097

Message
Unable to complete the operation because the memory size of the physical disk drive is less than the available or entered virtual disk size.
Detailed Description
A virtual disk cannot be created because the memory size of the physical disk drive is less than available or entered virtual disk size.
Recommended Response Action
Enter the FQDD of a physical disk drive that has a larger disk space, and then retry the operation. To view a list of physical disk drives and associated disk space, run the RACADM command "racadm storage get pdisks -o -p size". To view a list of virtual disks and associated size, run the RACADM command "racadm storage get vdisks -o -p size".
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR099

Message
Unable to find the FQDD arg1 because an invalid FQDD is entered or an operation is pending on the specified FQDD.
Arguments
  • arg1 = component FQDD
Detailed Description
The FQDD cannot be found because an invalid FQDD is entered or an operation is pending on the FQDD identified in the message.
Recommended Response Action
Do the following and then retry the operation: 1) Make sure the FQDD entered is valid. 2) Make sure an operation is not pending on the FQDD identified in the message. For more information refer to the RACADM Command Line Reference Guide.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR1

Message
A device arg1 is in an unknown state.
Arguments
  • arg1 = device name
Detailed Description
The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable, or a missing device, or a problem with the driver or firmware.
Recommended Response Action
See the storage hardware documentation for information on checking the cables. Check for problems with any enclosures attached to the system. Verify that the controller has a supported version of the driver and firmware. Rebooting the system may resolve this problem.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
2265
Server Administrator Trap ID
75300;80300;85300;90300;95300;100300;105300;110300;115300;120300

STOR12

Message
Chassis is operating with a disabled RAID controller.
Detailed Description
One or more RAID controllers is disabled. This prevents Fault Tolerant mode from operating.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
Trap/EventID
4179
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR2

Message
SCSI sense data arg1 .
Arguments
  • arg1 = args
Detailed Description
A SCSI device experienced an error, but may have recovered.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
Trap/EventID
4179
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR3

Message
CEM Storage Management has lost communication with the arg1 .
Arguments
  • arg1 = Controller Name
Detailed Description
Storage Management has lost communication with a controller. This may occur if the connectivity between the controller and iDRAC is disrupted or any underlying hardware problems are encountered.
Recommended Response Action
Reboot the system or iDRAC. If the problem is not resolved, contact technical support.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
Trap/EventID
4177
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR4

Message
CEM Storage Management encountered internal error.
Detailed Description
There was a software problem in initializing the CEM storage management components. Storage inventory and monitoring will be affected.
Recommended Response Action
Reboot the system or iDRAC. If the problem is not resolved, contact technical support.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 1 (Critical)
Trap/EventID
4177
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR5

Message
Redundancy lost. arg1
Arguments
  • arg1 = VD/Enclosure Name
Detailed Description
A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more physical disks included in the virtual disk have failed. Due to the failed physical disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an additional physical disk will result in lost data. In the case of an enclosure, more than one enclosure component has failed. For example, the enclosure may have suffered the loss of all fans or all power supplies.
Recommended Response Action
Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a failed or degraded component. Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components. Continue clicking the components with a Warning or Failed status until you identify the failed component. See Storage Health for more information. See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
2123
Server Administrator Trap ID
130600

STOR6

Message
CEM Storage Management detected inventory change(s) after host re-boot.
Detailed Description
A comparison of storage inventory collected before and after the host re-boot/re-set. reports differences. There could have been some storage components added or removed when the host was powered down.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
Trap/EventID
4179
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

STOR7

Message
The storage management instrumentation is performing an inventory refresh operation.
Detailed Description
The storage monitoring instrumentation detected a burst of events from underlying storage controllers. To overcome this overload condition, all the outstanding events have been purged and a fresh inventory will be performed automatically.
Recommended Response Action
No response action is required.
Category
Storage
Subcategory
STOR = Storage
Severity
Severity 3 (Informational)
Trap/EventID
4179
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\