Dell Chassis Management Controller Version 2.0 for PowerEdge FX2 and FX2s RACADM CLI Guide

PDF

chassisaction

Description

Runs a power action on the chassis or a switch.

To use this subcommand, you must have the Chassis Control Administrator privilege.

Synopsis

racadm chassisaction [-m <
                                                   module>] <
                                                   action>
                                                

Input

  • -m < module> — Module on which you want to carry out the action. Values are:
    • chassis — this is the default value, if -m is not specified.
    • switch-n, where n=1 to 2
  • < action> — Action that you want to run on the specified module. Values are:
    • powerdown — (Chassis only) Turns off the chassis.
    • powerup — (Chassis only) Turns on the chassis.
    • powercycle — Power cycles the module.
    • nongraceshutdown — (Chassis only) Non-gracefully turns off the chassis.
    • reset — Performs a hard reset of the module.

When < module > = switch, < action > must be powercycle or reset.

Output

None

Example

Perform a reset of switch-1:

racadm chassisaction -m switch-1 reset
Module power operation successful.