Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 2.0 for PowerEdge FX2 and FX2s RACADM CLI Guide

PDF

getled

Description

Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).

To use this subcommand, you must have the Login User privilege.

Synopsis

racadm getled -m < module>

Input

CMC only options:

-m < module > — Specifies the module whose LED settings you want to view.

< module > can be one of the following values:

  • server-<n> where n=1-4
  • server-<nx> where n=1-4; x=a-d (lower case)
  • switch-n where n=1 or 2
  • cmc-active

Example

For CMC:

  • racadm getled -m server-4

    < module> < LED state> server-4 Blinking

  • racadm getled -m chassis

    < module> < LED state> server-4 Not blinking

  • racadm getled -m server-1

    < module> < LED state> server-1 ON

  • racadm getled -m server-1

    < module> < LED state> server-1 Extension(1)