Description

Enables you to perform power management operations on the host system.

To use this subcommand, you must have the Execute Server Control Commands permission.

Synopsis

racadm serveraction -m <module> <action> 
racadm serveraction -a <action>

Input

  • -m< module> —

    server-n, where n=1–4

  • -a — Performs action on all servers. Not allowed with the powerstatus action.
  • < action> — Specifies the action. The options for the < action> string are:

    — graceshutdown — Performs a graceful shutdown of the server. If the operating system on the server cannot be cleanly shut down, this operation is not performed.

    — hardreset — Performs a reset (reboot) operation on the managed system.

    — powercycle — Issues a power-cycle operation on the managed system. This action is similar to pressing the power button on the system’s front panel to turn off, and then turn on the system.

    — powerdown — Turns off the managed system.

    — powerup — Turns on the managed system.

    — powerstatus — Displays the current power status of the server (ON or OFF).

    — reseat — Performs a virtual reseat of the server. This operation simulates reseating the server by resettig the iDRAC on a server.

    • NOTE: The reseat option is not available for individual FM120 servers.
  • NOTE: The -f option is required to force the ‘reseat’ action.
  • NOTE: The action powerstatus is not allowed with an -a option.

Output

Displays an error message if the requested operation fails, or a success message if the operation is completed.

Example

  • Turn off server 3 from the CMC.
    racadm serveraction -m server-3 powerdown

    Server power operation successful.

  • Turn off server 3 from iDRAC.
    racadm serveraction powerdown

    Server power operation successful

  • Turn off server 3 from CMC when power is already turned off on that server.
    racadm serveraction -m server-3 powerdown

    Server is already powered OFF.

  • Turn off the server from CMC when power is already turned off on that server.
    racadm serveraction powerdown

    Server is already powered OFF

  • Get Power Status of server 2 on CMC
    racadm serveraction -m server-2 powerstatus

    ON

  • Get Power status action on multinode server:
    racadm serveraction -m server-1a powerstatus
  • Get Power Status on iDRAC
    racadm serveraction powerstatus

    Server Power Status: ON

  • Reseat action on a multinode sled
    racadm serveraction -f -m sled-1 reseat
  • Explanation of Support

    CMC needs to support graceful shutdown

    The support of address individual blades is expected on the CMC


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\