RecoverPoint for VMs:vRPA NDUの交換が失敗する
Summary: vRPA2がサイト制御の場合、バージョン5.3からのNDU vRPA交換の失敗。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
NDU vRPAの交換が失敗します。
vRPA2のクラスター ロジックから:
2020/10/12 10:49:06.823 [https-openssl-nio-443-exec-7] (Base_5_1_CLAdapter.java:110) DEBUG - Checking connectivity... 2020/10/12 10:49:06.842 [https-openssl-nio-443-exec-7] (Base_5_1_CLAdapter.java:114) DEBUG - Got response from server, status code: 404, with message: null 2020/10/12 10:49:06.843 [https-openssl-nio-443-exec-7] (Base_5_1_CLAdapter.java:119) ERROR - isValidConnection - bad status code! failing connection... 2020/10/12 10:49:06.843 [https-openssl-nio-443-exec-7] (Base_5_1_CLAdapter.java:64) ERROR - initConnection - failed to reach RPA: xx.xx.xx.xx (down?) 2020/10/12 10:49:16.843 [https-openssl-nio-443-exec-7] (Base_5_1_CLAdapter.java:48) DEBUG - Connecting to rpa: xx.xx.xx.xx
Cause
vRPA2のDeployer APIは、vRPA1で古いエンドポイントを使用しています。
Resolution
回避 策:
NDUを交換する前に、vRPA2を再起動してvRPA1をサイト制御にします。
NDUの交換が失敗した場合は、vRPA2を再起動してvRPA1をサイト制御にし、NDUの交換を再試行します。
解像 度:
この問題は、RecoverPoint 5.3.1で対処されています。
アップグレードがお客様の環境に適しているかどうかを判断するには、Dell Technologiesカスタマー サポート センターまたはサービス担当者に連絡し、このソリューションIDを参照してください。
NDUを交換する前に、vRPA2を再起動してvRPA1をサイト制御にします。
NDUの交換が失敗した場合は、vRPA2を再起動してvRPA1をサイト制御にし、NDUの交換を再試行します。
解像 度:
この問題は、RecoverPoint 5.3.1で対処されています。
アップグレードがお客様の環境に適しているかどうかを判断するには、Dell Technologiesカスタマー サポート センターまたはサービス担当者に連絡し、このソリューションIDを参照してください。
Affected Products
RecoverPoint for Virtual MachinesArticle Properties
Article Number: 000180423
Article Type: Solution
Last Modified: 21 Nov 2023
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.