Connectrix Cisco: Switch is uitgeschakeld vanwege kernelpanic
Summary: MDS-switch was uitgeschakeld en niet opnieuw geladen na kernelpanic. Een gebruiker moest de switch handmatig inschakelen.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
De uitvoer van Stack-Trace toont slechts vijf van de zes CPU's online, waardoor Switch offline was en niet opnieuw werd geladen.
`show system reset-reason` ----- reset reason for module 1 (from Supervisor in slot 1) --- 1) At 65175 usecs after Tue Oct 13 02:48:39 2020 Reason: Kernel Panic Service: Version: 8.1(1a) ‘show logging nvram’ 2020 Oct 14 18:44:02.277 switch %SYSLOG-2-SYSTEM_MSG : Syslogs wont be logged into logflash until logflash is online 2020 Oct 14 18:44:05.851 switch %KERN-0-SYSTEM_MSG: [ 0.036807] Host controller irq 55 - kernel 2020 Oct 14 18:44:05.880 switch %KERN-0-SYSTEM_MSG: [ 0.057612] Assign root port irq 55 - kernel 2020 Oct 14 18:44:05.881 switch %KERN-0-SYSTEM_MSG: [ 0.057633] Host controller irq 54 - kernel 2020 Oct 14 18:44:05.883 switch %KERN-0-SYSTEM_MSG: [ 0.059007] Assign root port irq 54 - kernel 2020 Oct 14 18:44:05.912 switch %KERN-0-SYSTEM_MSG: [ 0.774555] Enabling all PCI devices - kernel ‘show logging onboard module stack-trace’ CPU 0 Call Trace: [b0463bc4] do_raw_spin_lock+0xec/0x120(unreliable) [b0698738] dev_watchdog+0x58/0x29c [b04324c4] call_timer_fn+0x48/0xfc [b0432770] run_timer_softirq+0x1f4/0x248 [b042af38] __do_softirq+0x16c/0x368 [b042b428] irq_exit+0x68/0x90 [b040a3c8] timer_interrupt+0x204/0x278 [b040f388] ret_from_except+0x0/0x18 CPU 1 Process: swapper/1 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 2 Process: sysinfo (pid 3855) Call Trace: [b0480d58] smp_call_function_many+0x268/0x274(unreliable) [b04182f8] flush_tlb_mm+0x58/0x68 [b042532c] copy_process.part.69+0xbb0/0x11a0 [b0425a84] do_fork+0xd0/0x318 [b040ecac] ret_from_syscall+0x0/0x3c CPU 3 Process: swapper/3 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48 CPU 4 Process: swapper/4 (pid 0) Call Trace: [b04230a4] cpm_idle_wait+0x14/0x24(unreliable) [b0469d4c] cpu_startup_entry+0x124/0x1e8 [b0410d78] start_secondary+0x1fc/0x200 [b0402234] start_secondary_47x+0x24/0x48
Cause
Een van de CPU's was offline, waardoor de Switch werd uitgeschakeld.
Resolution
Permanente oplossing:
- Als niet alle zes CPU's online zijn, vervangt u de switch en zorgt u ervoor dat de nieuwe switch wordt uitgevoerd op NX-OS v8.4(1a) of hoger.
- Als alle zes CPU's online zijn, moet u de firmware upgraden naar NX-OS v8.4(1a) of hoger om herhaling te voorkomen.
Additional Information
Dit is alleen van toepassing op Cisco MDS-9396s-switches.