PowerProtect Data Manager: VMware Application Aware backups fail with Lockbox Error

Summary: The purpose of this KB is to provide a solution to an issue where the first VMware Application Aware backup fails with Lockbox errors.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

PowerProtect Data Manager (PPDM) initial Application Aware backup fails

PPDM UI job's log displays:

TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure: A lockbox path was not specified, falling back to C:\Program Files\DPSAPPS\common\lockbox.
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure: 182243:msagentcon: Error encountered while retrieving information from the lockbox 'C:\Program Files\DPSAPPS\common\lockbox\agents.clb': The instance name key is missing from the Lockbox..
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure:
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure: 181469:msagentcon: The Data Domain Boost password cannot be saved into the lockbox.
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure:
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure: Configure the certificate authorization for PowerProtect Data Manager server '<PPDM_IP_OR_FQDN>'.
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure: 181389:msagentcon:Unable to execute discovery command, error: 'Unable to update persisted settings for Data Domain host '<DD_IP_OR_FQDN>': The Data Domain Boost password cannot be saved into the lockbox.
TRACE:  [PowerProtect] MSSQLDM: MSSQLDM:configure: ', 'Unable to update persisted settings for PowerProtect Data Manager host '<PPDM_IP_OR_FQDN>': Exception 'Unable to store the ROOT_CERT to lockbox.' occurred while sending Certificate Signing Request.

 

Cause

A previous version of the Microsoft SQL Application Direct software was installed at a point in time. When it is removed from the computer, the old lockbox was left behind. The current version of the software is not able to update older lockboxes.

This issue may happen where older versions of the software were used or transitioning from Microsoft SQL Application Direct Backups to VMware Application Aware backups occurred.

 

Resolution

  1. Rename the lockbox directory

    ren  C:\Program Files\DPSAPPS\common\lockbox C:\Program Files\DPSAPPS\common\lockbox,previous
  2. Retry the backup

Note: The lockbox directory is recreated at the beginning of the next backup.

 

Produse afectate

PowerProtect Software

Produse

PowerProtect X400 Appliance, PowerProtect Software
Proprietăți articol
Article Number: 000078379
Article Type: Solution
Ultima modificare: 07 nov. 2025
Version:  4
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.