ESXi host reboot and VM migration takes more time longer than expected

Description
An ESXi host configured with iSCSI LUN takes more time longer than expected to complete ESXi reboot, or VM migrations, and VM power-on operations. These issues are observed for the below configuration:
  • BCM 5719/BCM 5720 NICs are used for the iSCSI traffic
  • No network switch between the ESXi host and iSCSI storage array
  • Jumbo frames are configured on ESXi host and storage array
Workaround
Not applicable