PowerStore: I/O to Volume Using non-affinity Node During Snapshot Creation May Cause Module PANIC

Summary: A host sending I/O to a volume through a non-affinity node during snapshot creation may cause module PANIC.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • An internal software module may restart, or a node may reboot unexpectedly during snapshot creation by a scheduler or with the replication functionality.
  • This can result in an auto-recovering data unavailability (DU) condition due to multiple internal software module restarts on both nodes.

Cause

During snapshot creation, if a host sends I/O to a volume through a non-affinity node, it may run into a cache lock fairness issue. This may cause an internal module restart or node reboot.

Resolution

  • Verify that the host multipath settings are configured according to Dell Technologies guidelines. PowerStore is not an active/active array, and multipath should always be configured as Asymmetric Logical Unit Access (ALUA).
  • Contact Dell Technical Support for further assistance.

Affected Products

PowerStore, PowerStoreOS
Article Properties
Article Number: 000224343
Article Type: Solution
Last Modified: 30 May 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.