Avamar: Falha na GLR do Hyper-V com "Failed to Get Security attributes for VHD file"

Summary: Este artigo detalha a possível falha de GLR (Granular Level Recovery, recuperação em nível granular) do Hyper-V e um possível novo hotfix.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

A montagem glR (Granular Level Recovery, recuperação em nível granular) da máquina virtual (VM) do Hyper-V falha com mensagens semelhantes às seguintes:
De axionfs.log:

axionfs Error <10900>: cbfs_get_file_security: function called with invalid parameter.

Na avhyperv_plugin.log:

avhypervglr Info <18750>: Failed to mount VM <DELLEMC>
avhypervglr Error <13794>: Hyper -V GLR Service had the following error = STATE_EVENT_IGNORED - Ignoring requested state transition for the 'plugin_mount_vm' event with transition cause of 'CAUSE_MOUNT_NEW_VOLUME' while in the 'STATE_NEEDS_REBOOT' state
avhypervglr Error <15458>: Unable to mount VHDs

Na avhypervglrsvc.log:

 [avhypervglrsvc.exe] Fetching Virtual Disk properties for 'C:\Program Files\avs\var\avfscache\AVFSMOUNT\00000001\d$\VM\Hyper-V\Virtual Hard Disks\DELLEMC_592A3536-12B2-4555-9850-A8D2A1B9D816.avhdx' with volume mappings set to 'false'.
avhypervglrsvc.exe Info <42422>: Unable to get Virtual Disk Information. OpenVirtualDisk failed with error (3): The system cannot find the path specified.

[avhypervglrsvc.exe] hypervvss_vdisk::set_vdisk_parent -> in_path='C:\Program Files\avs\var\avfscache\AVFSMOUNT\00000001\d$\VM\Hyper-V\Virtual Hard Disks\DELLEMC_592A3536-12B2-4555-9850-A8D2A1B9D816.avhdx', in_parent_path='C:\Program Files\avs\var\avfscache\AVFSMOUNT\00000001\d$\VM\Hyper-V\Virtual Hard Disks\DELLEMC.vhdx'.
avhypervglrsvc.exe Error <42422>: Unable to set Virtual Disk Parent Path. OpenVirtualDisk failed with error (3): The system cannot find the path specified.

CoInitializeSecurity Failed because it has been already called by this thread
avhypervglrsvc.exe Info <13669>: VDS Service Completed. Result = The operation completed successfully.
avhypervglrsvc.exe Info <13686>: Mounting VHD file path = C:\Program Files\avs\var\avfscache\AVFSMOUNT\00000001\d$\VM\Hyper-V\Virtual Hard Disks\DELLEMC_592A3536-12B2-4555-9850-A8D2A1B9D816.avhdx
avhypervglrsvc.exe Error <13701>: Failed to Get Security attributes for VHD file 'C:\Program Files\avs\var\avfscache\AVFSMOUNT\00000001\d$\VM\Hyper-V\Virtual Hard Disks\DELLEMC_592A3536-12B2-4555-9850-A8D2A1B9D816.avhdx'. Error = A device attached to the system is not functioning.
avhypervglrsvc.exe Error <13687>: Unable to get security attributes for file = C:\Program Files\avs\var\avfscache\AVFSMOUNT\00000001\d$\VM\Hyper-V\Virtual Hard Disks\DELLEMC_592A3536-12B2-4555-9850-A8D2A1B9D816.avhdx
avhypervglrsvc.exe Error <13693>: AddVDisk returned error The system cannot find the path specified.
 [] No more virtual disk provider found
avhypervglrsvc.exe Error <13680>: Failed to query Provider
avhypervglrsvc.exe Error <13678>: Failed to mount vhd disk
[avhypervglrsvc.exe] xml = C:\Program Files\avs\var
 avhypervglrsvc.exe Info <15441>: Failed to find disk at index = 1

Em ambientes de alguns usuários, isso também pode fazer com que os servidores GLR ou proxies do Windows reinicializem durante a tentativa de navegação.

Cause

Os plug-ins GLR do Avamar para Hyper-V, Exchange, SharePoint e SQL (TLR) têm um "driver ELDOS" incorporado de driver de terceiros.

Esse componente é necessário para montar o caminho de backup do Avamar de um banco de dados para realizar as operações glr ou TLR concluídas posteriormente com a ferramenta Itempoint.

Esse driver ELDOS está em uma versão anterior que não tem os aprimoramentos mais recentes para dar suporte a sistemas operacionais Windows mais recentes (Windows 2022 e posterior). Isso causa as falhas mencionadas acima.

Como consequência, a recuperação glr ou TLR não é compatível com o Windows 2022 e versões posteriores, também refletida na matriz de suporte do Avamar.

As equipes de engenharia e gerenciamento de produtos da Dell estão avaliando alternativas para obter as melhores opções viáveis.

Resolution

Quando houver uma atualização para essa situação, este artigo, juntamente com a Matriz de suporte do Avamar, será atualizado adequadamente.

Solução temporária:
Para executar a GLR de um banco de dados, primeiro recupere o banco de dados em um arquivo e, em seguida, use a ferramenta Itempoint para minerar os dados.