PowerStore: SCSI LUN RESET command did not complete in time resulting in Module PANIC
概要: An unexpected internal software Module PANIC may be observed if SCSI LUN RESET command does not complete in time.
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
現象
An unexpected internal software Module PANIC may be observed if SCSI LUN RESET command does not complete in time (19 seconds).
This condition may occur when SCSI LUN RESET commands are issued by hosts for various environmental reasons.
In addition to the above condition, this symptom tends to occur when the PowerStore is under heavy load such as during performance testing or when migrating data from external storage using the PowerStore Import functionality.
In addition to the above conditions, this symptom tends to occur when several SCSI UNMAP or SCSI RESERVATION requests are sent by the hosts in the same timeframe.
This condition may occur when SCSI LUN RESET commands are issued by hosts for various environmental reasons.
In addition to the above condition, this symptom tends to occur when the PowerStore is under heavy load such as during performance testing or when migrating data from external storage using the PowerStore Import functionality.
In addition to the above conditions, this symptom tends to occur when several SCSI UNMAP or SCSI RESERVATION requests are sent by the hosts in the same timeframe.
原因
Due to the current timeout value defined for the SCSI LUN RESET command in the PowerStore, under certain conditions, if SCSI LUN RESET processing is not completed within 19 seconds on a node, it may result in the software module panic.
解決方法
This issue is fixed in PowerStoreOS 3.5.0 by increasing the timeout value for SCSI LUN RESET command from 19 seconds to 1 minute.
Workaround
Reducing intensive, heavy, workloads from the hosts or from the external storage if it is connected, reduces the possibility of this symptom occurring.
For assistance contact technical support
Workaround
Reducing intensive, heavy, workloads from the hosts or from the external storage if it is connected, reduces the possibility of this symptom occurring.
For assistance contact technical support