Description
A fatal error on bus number 02, device number 00, and function number 0 (BDF 2:0.0) is observed in the following configurations:
  • When a graceful shutdown action is initiated.
  • In Gnome settings, under the Suspend & Power Button section, the When the Power Button is pressed option is set to Suspend.
Cause
The NIC continues to perform DMA operations even after device goes into a D3hot state.
Workaround
Set the When the Power Button is pressed option to Power Off or Nothing.
Solution
The issue is resolved in Red Hat Enterprise Linux 8.2
Systems affected
All Dell EMC PowerEdge servers that support BCM574xx series NICs.