Dell PowerEdge Systems Red Hat Enterprise Linux 8 Release Notes

Link Up message is observed when the NVMe device slot is powered off and the device is unplugged

Description
The message Link Up is observed in the dmesg log when the NVMe device slot is powered off and the device is unplugged by running the following command:
echo 0 > /sys/bus/pci/slots/<slot number>/power
The expected message is Link Down because the device is unplugged.
Cause
This is due to an issue with the pciehp driver.
Workaround
This issue is a cosmetic issue and can be ignored. The NVMe device is recognized when plugged into the slot.
Systems affected
Dell EMC PowerEdge R740xd and Dell EMC PowerEdge R7425
Applies to
Red Hat Enterprise Linux 8.0 and later
Tracking number
160773