Description
The execution of dmidecode command displays an OUT OF SPEC message in the Slot Type and Slot Length fields of the SMBIOS system slots (Type 9) structure.
Cause
The dmidecode tool does not recognize the 0x5h and 0x6h values in the Slot Length field and 0x20h value in the Slot Type field in SMBIOS specification version 3.0.0.
Workaround
Not available
Solution
The issue is resolved in Red Hat Enterprise Linux 8.2
Systems affected
Dell PowerEdge R6515, Dell PowerEdge R7515, Dell PowerEdge R6525, and Dell PowerEdge R7525
Applies to

Red Hat Enterprise Linux 8.0 kernel-4.18.0-80.7.1.el8 or later

Tracking number
150263, 157470, 157474