Network Settings

To view the Network Settings screen, power on the system, press F2, and click System Setup Main Menu > System BIOS > Network Settings.
NOTE:Network Settings are not supported in BIOS boot mode.
Table 1. Network Settings detailsThis table provides the details of the options available on the Network Settings screen.
Option Description
UEFI PXE Settings Enables you to control the configuration of the UEFI PXE device.
Number of PXE Devices This field specifies the number of PXE devices. This option is set to 4 by default.
PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI PXE boot option is created for the device.
PXE Device n Settings(n = 1 to 4) Enables you to control the configuration of the PXE device.
UEFI HTTP Settings Enables you to control the configuration of the UEFI HTTP device.
HTTP Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI HTTP boot option is created for the device.
HTTP Device n Settings (n = 1 to 4) Enables you to control the configuration of the HTTP device.
UEFI iSCSI Settings Enables you to control the configuration of the iSCSI device.
iSCSI Initiator Name Specifies the name of the iSCSI initiator in IQN format.
iSCSI Device1 Enables or disables the iSCSI device. When disabled, a UEFI boot option is created for the iSCSI device automatically. This is set to Disabled by default.
iSCSI Device1 Settings Enables you to control the configuration of the iSCSI device.
UEFI NVMe-oF Settings Enables you to control the configuration of the NVMe-oF devices.
NVMe-oF Enables or disables the NVMe-oF feature. When enabled, it allows to configure the host and target parameters needed for fabric connection. This is set to Disabled by default.
NVMe-oF Host NQN This field specifies the name of the NVMe-oF host NQN. Allowed input is in the following format: nqn.yyyy-mm.<Reserved Domain Name>:<Unique String>. Leave it empty to use system generated value with following format: nqn.1988-11.com.dell:<Model name>.<Model number>.<Service Tag>.
NVMe-oF Host Id This field specifies a 16 bytes value of the NVMe-oF host identifier that uniquely identifies this host with the controller in the NVM subsystem. Allowed input is a hexadecimal-encoded string in this format: 00112233-4455-6677-8899-aabbccddeeff. Leave it empty to use system generated value. A value of all FF is not allowed.
Host Security Key Path This field specifies the Host security key path.
NVMe-oF SubSystem Settings This field controls the parameters for the NVMe-oF subsystem n connections.
Table 2. PXE Device n Settings detailsThis table provides the details of the options available on the UEFI PXE Device n Settings screen.
Option Description
Interface Specifies NIC interface used for the PXE device.
Protocol Specifies Protocol used for PXE device. This option is set to IPv4 or IPv6. This option is set to IPv4 by default.
Vlan Enables Vlan for PXE device. This option is set to Enabled or Disabled. This option is set to Disabled by default.
Vlan ID Shows the Vlan ID for the PXE device
Vlan Priority Shows the Vlan Priority for the PXE device.
Table 3. HTTP Device n Settings detailsThis table provides the details of the options available on the UEFI HTTP Device n Settings screen.
Option Description
Interface Specifies NIC interface used for the HTTP device.
Protocol Specifies Protocol used for HTTP device. This option is set to IPv4 or IPv6. This option is set to IPv4 by default.
Vlan Enables Vlan for HTTP device. This option is set to Enable or Disable. This option is set to Disable by default.
Vlan ID Shows the Vlan ID for the HTTP device
Vlan Priority Shows the Vlan Priority for the HTTP device.
DHCP Enables or disables DHCP for this HTTP device. This option is set to Enabled by default.
IP Address Specifies IP address for the HTTP device.
Subnet Mask Specifies subnet mask for the HTTP device.
Autoconfiguration Enables or disables the IPv6Autoconfiguration for the HTTP Device. When set to Enabled, IPv6 Address and Gateway are retrieved from Autoconfiguration mechanism.
Prefix Length IPv6 Prefix Length (0~127) for this HTTP Device.
IPv6 Address IPv6 Unicast address for this HTTP Device.
Gateway Specifies gateway for the HTTP device.
DNS info via DHCP Enables or disables DNS Information from DHCP. This option is set to Enabled by default.
Primary DNS Specifies the primary DNS server IP address for the HTTP Device.
Secondary DNS Specifies the secondary DNS server IP address for the HTTP Device.
URI (will obtain from DHCP server if not specified) Obtain URI from the DHCP server if not specified
TLS Authentication Configuration Specifies the option for TLS authentication configuration.
NOTE:Autoconfiguration, Prefix Length and IPv6 Address options are visible only when Protocol is set to IPv6
Table 4. ISCSI Device1 Settings screen detailsThis table provides the details of the options available on the ISCSI Device1 Settings screen.
Option Description
Connection 1 Enables or disables the iSCSI connection. This option is set to Disabled by default.
Connection 2 Enables or disables the iSCSI connection. This option is set to Disabled by default.
Connection 1 Settings Enables you to control the configuration for the iSCSI connection.
Connection 2 Settings Enables you to control the configuration for the iSCSI connection.
Connection Order Enables you to control the order for which the iSCSI connections will be attempted.
Table 5. TLS Authentication Configuration screen detailsThis table provides the details of the options available on the TLS Authentication Configurationscreen.
Option Description
TLS Authentication Mode View or modify the device's boot TLS Authentication Mode. This option is set to One Way by default. None means the HTTP server and the client will not authenticate each other for this boot.
Root Certificate Configuration Import, delete, or export the root certificate.
Table 6. NVMe-oF SubSystem Settings screen detailsThis table provides the details of the options available on the NVMe-oF SubSystem Settingsscreen.
Option Description
NVMe-oF SubSystem n (n = 1 to 4) Enables or disables NVMe-oF SubSystem. This option is set to Disabled by default.
NVMe-oF SubSystem n Settings (n = 1 to 4) Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Table 7. NVMe-oF SubSystem n SettingsThis table provides the details of the options available on the NVMe-oF SubSystem n Settings screen.
Option Description
Interface NIC interface used for NVMe-oF connections. This option is set to Embedded NIC 1 Port 1 Partition 1 by default.
Transport Type This field sets the value of transport type for NVMe-oF connection. This option is set to TCP by default.
Protocol This field sets the value of protocol type for NVMe-oF connection. This option is set to IPv4 by default. When IPv6 is selected, IPv6 Autoconfiguration is used to get the IPv6 address.
VLAN Enables or disables VLAN for this NVMe-oF connections. This option is set to Disabled by default.
VLAN Id Specifies the VLAN Id for this NVMe-oF connection. This option is set to 1 by default.
VLAN Priority Specifies the VLAN priority for this NVMe-oF connection. This option is set to 0 by default.
Retry Count Specifies the retry count for this NVMe-oF connection. This option is set to 3 by default.
Timeout Specifies the time out for this NVMe-oF connection. This option is set to 10000 by default.
DHCP NVMe-oF connection gets subsystem's information from the DHCP server. This option is set to Disabled by default.
Host IP Address Specifies the Host IP Address for this NVMe-oF connection.
Host Subnet Mask Specifies the Host Subnet Mask for this NVMe-oF connection.
Host Gateway Specifies the Host Gateway for this NVMe-oF connection.
NVMe-oF subsystem info via DHCP Enables and disables the NVMe-oF subsystem's DHCP for this connection. This option is set to Disabled by default.
NVMe-oF subsystem NQN Specifies the NVMe-oF subsystem's NQN for this connection.
NVMe-oF subsystem Address Specifies the NVMe-oF subsystem's IP address for this connection.
NVMe-oF subsystem Port Specifies the NVMe-oF subsystem's port for this connection. If subsystem NQN is empty, this field will be forced to the default Discovery Service port 8009.This option is set to 4420 by default.
NVMe-oF subsystem NID Specifies the NamespaceID (NID) for this NVMe-oF connection.
NVMe-oF subsystem Controller ID Specifies the NVMe-oF subsystem's Controller ID for this connection. This option is set to 0 by default.
Security Enables or disables the security option for this NVMe-oF connection. This option is set to Disabled by default.
Authentication Type Specifies the authentication type for this NVMe-oF connection. This option is set to None by default.
Securitykeypath Specifies the Securitykeypath for this NVMe-oF connection.