Dell PowerEdge R760 Installation and Service Manual

Status LED indicators

NOTE:The indicators display solid amber if any error occurs.
Figure 1. Status LED indicators
This image shows status LED indicators.
Table 1. Status LED indicators and descriptions Item 1 is the drive indicator, that flashes amber if an error occurs related to drive. Item 2 is the temperature indicator that flashes amber if a thermal error occurs (for example, a temperature out of range or fan failure). Item 3 is the electrical indicator that flashes amber if an electrical error occurs (for example, voltage out of range, or a failed power supply unit or voltage regulator). Item 4 is the memory indicator that flashes amber if a memory error occurs. Item 5 is the PCIe indicator that flashes amber if an error occurs related to PCIe card.
Icon Description Condition Corrective action
icon for hard drive indicatorDrive indicator The indicator turns solid amber if there is a drive error.
  • Check the System Event Log to determine if the drive has an error.
  • Run the appropriate Online Diagnostics test. Restart the system and run embedded diagnostics (ePSA).
  • If the drives are configured in a RAID array, restart the system, and enter the host adapter configuration utility program.
icon for temperature indicatorTemperature indicator The indicator turns solid amber if the system experiences a thermal error (for example, the ambient temperature is out of range or there is a fan failure). Ensure that none of the following conditions exist:
  • A cooling fan has been removed or has failed.
  • System cover, air shrouds, or back filler bracket has been removed.
  • Ambient temperature is too high.
  • External airflow is obstructed.
If the problem persists, see the Getting help section.
icon for electrical indicatorElectrical indicator The indicator turns solid amber if the system experiences an electrical error (for example, voltage out of range, or a failed power supply unit (PSU) or voltage regulator). Check the System Event Log or system messages for the specific issue. If it is due to a problem with the PSU, check the LED on the PSU. Reseat the PSU.

If the problem persists, see the Getting help section.

icon for memory indicatorMemory indicator The indicator turns solid amber if a memory error occurs. Check the System Event Log or system messages for the location of the failed memory. Reseat the memory module.

If the problem persists, see the Getting help section.

icon for PCIe indicatorPCIe indicator The indicator turns solid amber if a PCIe card experiences an error. Restart the system. Update any required drivers for the PCIe card. Reinstall the card.

If the problem persists, see the Getting help section.

NOTE:For more information about the supported PCIe cards, see the Expansion cards and expansion card risers > Expansion card installation guidelines section.