跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems User’s Guide

Clustering setup in Windows

The following registry entries are required on each node of the cluster to enable them to see the drives on the Shared PERC 8:

Table 1. Registry entries . This table describes the Registry entries.
Location Entry type Property Value
HKLM\SYSTEM\CurrentControlSet\Services\ClusDisk\Parameters DWORD AllowBusTypeRAID 0X01

Cluster Setting: QuorumArbitrationTimeMax = 90

This value shall be increased to 90 from a default value of 20. This allows the clustered solution to tolerate a controller failover, which can sometimes take up to 80 seconds.

To change the QuorumArbitrationTimeMax registry value using PowerShell for Windows Server 2012 and Windows Server 2012 R2, do the following:
  1. From a cluster node, open an elevated PowerShell prompt.
  2. Run the following command with the appropriate value: Get-Cluster | %{ $_. QuorumArbitrationTimeMax = 90}
  3. To confirm the QuorumArbitrationTimeMax value has changed on the cluster run: Get-Cluster | fl *
For more details on setting up clustering in Windows environments, see Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX .