Two existing non-fault
tolerant controllers (connected to two enclosures each) to fault tolerant
configuration.
-
NOTE: In a dual controller
fault tolerant configuration, a maximum of two enclosures are supported.
This scenario results in a loss of two enclosures.
-
Turn off the server modules. Click
Server Overview → Power → Control → Power Off Server for
every server.
-
Click
Chassis Overview → Storage
→ Controllers → Troubleshooting → Actions → Enable Fault Tolerance
to enable Enable Fault Tolerance for both controllers.
An error message appears stating that the
controllers are not Fault Tolerant because the peer controller is
not available. This is expected.
-
Click
Chassis Overview → Power →
Control → Power Off System
to turn off the chassis.
-
Cable enclosure(s) to Shared PERC 8 External
cards using required cabling methodology.
-
NOTE: Only two enclosures are supported in a dual controller fault tolerant
configuration.
-
NOTE: This cabling topology
is required for fault tolerance to function.
-
Click
Chassis Overview → Power
→ Control → Power On System
to turn on the chassis.