跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems User’s Guide

Replacing a Shared PERC 8 External card

When replacing an existing Shared PERC 8 External card in the PowerEdge VRTX system, perform the following steps to ensure proper functionality of the shared storage after the replacement process is complete.
  1. Prerequisites for removing the Shared PERC External card. See Prerequisites for removing the Shared PERC 8 External card .
  2. Remove the Shared PERC External card. See Removing the Shared PERC 8 External card .
  3. Install the Shared PERC External card. See Installing the Shared PERC 8 External card .
  4. Postinstallation tasks for the Shared PERC External card. See Postinstallation tasks for the Shared PERC 8 External card .
  • CAUTION: Shared PERC 8 External cards are hot add supported, but are not hot remove supported. Do not remove Shared PERC 8 External cards from the system board while the PowerEdge VRTX system is turned on.

In the Single Shared PERC 8 External card configuration, the shared PERC External slot is labeled as Slot 5 or Slot 6 (either can be used) on the PowerEdge VRTX system board. In the Fault Tolerant Shared PERC 8 External card configuration, the shared PERC External slots are labeled as Slot 5 and Slot 6 on the PowerEdge VRTX system board.

To locate the Shared PERC slots, see System Board Connectors in the Dell PowerEdge VRTX Enclosure Owner's Manual at Dell.com/poweredgemanuals.

For more information, see the storage subsystem compatibility matrix document at Dell.com/support/home.

For information on removing and reinstalling system parts, see the VRTX Enclosure Owner's Manual of the system at Dell.com/poweredgemanuals.