Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems User’s Guide

SMART error detected on a physical disk in a nonredundant virtual disk

Issue:
A SMART error is detected on a physical disk in a nonredundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Physically remove the physical disk that detected the SMART error.
    • NOTE: The virtual disk will be in a Failed state after the physical disk is removed. Ensure you back up your data before performing this operation.
  3. Replace the affected physical disk with a new physical disk of equal or higher capacity.
  4. Delete the failed virtual disk and recreate the virtual disk with the same members.
    • NOTE: For information on creating and deleting virtual disks, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at Dell.com/esmmanuals.
  5. Restore from the backup.