PowerProtect: Replication fails "Err: 5009 file-copy operation failed (nfs: "I/O" error)"

Summary: PowerProtect Data Manager: The replication failed with the error "Err: 5009 file-copy operation failed (nfs: "I/O" error)"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Manager logs:

Err: 5009 file-copy operation failed (nfs: "I/O" error)

Data Domain logs:

Failed to do a filecopy, err = [5029: rpc operation/function failure, ddr/repl/lrepl_client.c, filecopy_handle_scaleout, 14606]

The port 2051 is open between Data Domains. The replication process from PowerProtect Data Manager reaches 99%, but 0-byte data is transferred until failed after 20 times reties. 

Cause

Switch MTU: 1500
DD Network card MTU: 9000

Resolution

The MTU on the switch must be the same as Data Domain.

Affected Products

PowerProtect Data Manager
Article Properties
Article Number: 000225799
Article Type: Solution
Last Modified: 11 Dec 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.