PowerProtect Data Manager -Failed to create storage unit with error code CFG0001

Summary: PowerProtect Data Manager -Failed to create storage unit with error code CFG0001

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

새 정책을 생성할 때 스토리지 유닛을 생성하지 못했습니다.

GUI에서 다음을 수행합니다.
CFG0001: xxx: Unable to configure the protection policy because of the following error: Failed to connect to PowerProtect DD System. errorNum: 5007 errorMessage: operation is not implemented


작업 로그에서 다음을 수행합니다.
ddboost.log: 2023-08-11T23:15:17.931Z ERROR [] [pool-26-thread-1] [00000000-0000-4000-b000-000000000000][][][TRACE_ID:81a3388041e49793;JOB_ID:9ea4884359c07119][plc.id:2eab4e3d,asset.id:,pcs.id:] ddboost.log(52) -  severity:1 msg:[D688:7FF690077BA0] ddp_connect_with_config() failed, Hostname: xxx, Err: 5007-nfs ddp getinfo failed (nfs: Operation not supported) 


네트워크 문제, 인증서 문제 없음, 이미 sysadmin을 사용하여 DD를 추가하는 것을 이미 확인했습니다(검색이 정상적으로 작동).


Cause

DD NFS 서비스가 비활성화되어 있습니다.

image.png

Resolution

DD GUI에서 "ENABLE"를 클릭하여 NFSv3를 활성화합니다.

Affected Products

PowerProtect Data Manager, PowerProtect Software
Article Properties
Article Number: 000216695
Article Type: Solution
Last Modified: 27 Nov 2023
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.