Symptoms

建立新原則時,我們無法建立儲存裝置。

從 GUI:
CFG0001: xxx: Unable to configure the protection policy because of the following error: Failed to connect to PowerProtect DD System. errorNum: 5007 errorMessage: operation is not implemented


從工作記錄:
ddboost.log: 2023-08-11T23:15:17.931Z ERROR [] [pool-26-thread-1] [00000000-0000-4000-b000-000000000000][][][TRACE_ID:81a3388041e49793;JOB_ID:9ea4884359c07119][plc.id:2eab4e3d,asset.id:,pcs.id:] ddboost.log(52) -  severity:1 msg:[D688:7FF690077BA0] ddp_connect_with_config() failed, Hostname: xxx, Err: 5007-nfs ddp getinfo failed (nfs: Operation not supported) 


我們已經確認沒有網路問題,沒有憑證問題,已經使用 sysadmin 新增 DD (探索運作正常)


Cause

DD NFS 服務已停用。

image.png

Resolution

在 DD GUI 上,按一下[ENABLE] (啟用) 以啟用 NFSv3

Affected Products