Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC Configuration Guide for the S4048T–ON System 9.14.2.4

PDF

Displaying Information about a Stack

To display information about the stack, use the following command.

  • Display for stack-identity, status, and hardware information on every unit in a stack.
    EXEC Privilege mode
    show system
  • Display most of the information in show system, but in a more convenient tabular form.
    EXEC Privilege mode
    show system brief
  • Display the same information in show system, but only for the specified unit.
    EXEC Privilege mode
    show system stack-unit
  • Display topology and stack link status for the entire stack.
    EXEC Privilege mode
    show system stack-ports [status | topology]

Examples of the show system Commands

Display information about a switch stack using the show system command.

The following is an example of the show system command to view the stack details.

DellEMC#show system 

Stack MAC                  : 34:17:eb:f2:94:c4
Reload-Type                : normal-reload [Next boot : normal-reload]

--  Unit 1 --
Unit Type                  : Management Unit
Status                     : online 
Next Boot                  : online 
Required Type              : S4048-ON - 54-port TE/FG (SK-ON)
Current Type               : S4048-ON - 54-port TE/FG (SK-ON)
Master priority            : 14 
Hardware Rev               : 2.0 
Num Ports                  : 72 
Up Time                    : 33 min, 51 sec
Dell Networking OS Version : 1-0(0-5005) 
Jumbo Capable              : yes 
POE Capable                : no 
FIPS Mode                  : disabled 
Burned In MAC              : 34:17:eb:f2:94:c4 
No Of MACs                 : 3

--  Power Supplies  --
Unit   Bay   Status       Type    FanStatus   FanSpeed(rpm)
---------------------------------------------------------------------------
  1     1    up           UNKNOWN up          10704
  1     2    absent               absent      0

--  Fan  Status  --
Unit Bay   TrayStatus  Fan1    Speed   Fan2    Speed   
------------------------------------------------------------------------------------
1    1     up          up      10134   up      10031   
1    2     up          up      10031   up      10031   
1    3     up          up      10031   up      10031   

Speed in RPM

--  Unit 2 --
Unit Type                  : Standby Unit
Status                     : online 
Next Boot                  : online 
Required Type              : S4048-ON - 54-port TE/FG (SK-ON)
Current Type               : S4048-ON - 54-port TE/FG (SK-ON)
Master priority            : 10 
Hardware Rev               : 2.0 
Num Ports                  : 72 
Up Time                    : 33 min, 52 sec
Dell Networking OS Version : 1-0(0-5005) 
Jumbo Capable              : yes 
POE Capable                : no 
FIPS Mode                  : disabled 
Burned In MAC              : 34:17:eb:f2:83:c4 
No Of MACs                 : 3

--  Power Supplies  --
Unit   Bay   Status       Type    FanStatus   FanSpeed(rpm)
---------------------------------------------------------------------------
  2     1    up           UNKNOWN up          10768
  2     2    down         UNKNOWN down        0

--  Fan  Status  --
Unit Bay   TrayStatus  Fan1    Speed   Fan2    Speed   
------------------------------------------------------------------------------------
2    1     up          up      10031   up      10031   
2    2     up          up      10031   up      10031   
2    3     up          up      10134   up      10031   

Speed in RPM

--  Unit 3 --
Unit Type                  : Member Unit
Status                     : online 
Next Boot                  : online 
Required Type              : S4048-ON - 54-port TE/FG (SK-ON)
Current Type               : S4048-ON - 54-port TE/FG (SK-ON)
Master priority            : 5 
Hardware Rev               : 2.0 
Num Ports                  : 72 
Up Time                    : 33 min, 45 sec
Dell Networking OS Version : 1-0(0-5005) 
Jumbo Capable              : yes 
POE Capable                : no 
FIPS Mode                  : disabled 
Burned In MAC              : 34:17:eb:f2:99:c4 
No Of MACs                 : 3

--  Power Supplies  --
Unit   Bay   Status       Type    FanStatus   FanSpeed(rpm)
---------------------------------------------------------------------------
  3     1    up           UNKNOWN up          10704
  3     2    absent               absent      0

--  Fan  Status  --
Unit Bay   TrayStatus  Fan1    Speed   Fan2    Speed   
------------------------------------------------------------------------------------
3    1     up          up      10031   up      10031   
3    2     up          up      9929    up      10031   
3    3     up          up      10031   up      10134   

Speed in RPM

DellEMC#  

The following is an example of the show system brief command to view the stack summary information.

DellEMC#show system brief

Stack MAC                  : 34:17:eb:f2:94:c4
Reload-Type                : normal-reload [Next boot : normal-reload]

--  Stack Info  --
Unit  UnitType     Status         ReqTyp          CurTyp          Version     Ports
------------------------------------------------------------------------------------
  1   Management   online         S4048-ON        S4048-ON        1-0(0-5005)  72     
  2   Standby      online         S4048-ON        S4048-ON        1-0(0-5005)  72     
  3   Member       online         S4048-ON        S4048-ON        1-0(0-5005)  72     
  4   Member       not present                    
  5   Member       not present                    
  6   Member       not present                    

--  Power Supplies  --
Unit   Bay   Status       Type    FanStatus   FanSpeed(rpm)
---------------------------------------------------------------------------
  1     1    up           UNKNOWN up          10736
  1     2    absent               absent      0
  2     1    up           UNKNOWN up          10768
  2     2    down         UNKNOWN down        0
  3     1    up           UNKNOWN up          10672
  3     2    absent               absent      0

--  Fan  Status  --
Unit Bay   TrayStatus  Fan0    Speed   Fan1    Speed   
------------------------------------------------------------------------------------
1    1     up          up      10134   up      10031   
1    2     up          up      10031   up      9929    
1    3     up          up      10031   up      10031   
2    1     up          up      10031   up      10031   
2    2     up          up      10031   up      10031   
2    3     up          up      10031   up      10134   
3    1     up          up      10031   up      10134   
3    2     up          up      10031   up      10031   
3    3     up          up      10031   up      10031   

Speed in RPM
DellEMC#

The following example shows the show system stack-ports command.

DellEMC#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin  Link   Trunk
                     (Gb/s)     Status Status Group
------------------------------------------------------------------
1/56      3/56        40        up     up
1/60      3/60        40        up     up
3/48                  40        up     down
3/52                  40        up     down
3/56      0/56        40        up     up
3/60      0/60        40        up     up

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\