Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerVault ME4 Series Storage System CLI Guide

PDF

test

Description Sends a test message to configured destinations for event notification and managed logs. After issuing this command, verify that the test message reached its destinations.
Minimum role manage
Syntax

test

email|managedlogs|managedlogswarn|managedlogswrap|notification|snmp [region crash1|crash2|crash3|crash4|ecdebug|mc|scdebug]

Output email|managedlogs|managedlogswarn|managedlogswrap|notification|snmp
  • email: This option behaves the same as the notification option and remains for backward compatibility only.
  • managedlogs: Specify this option to test receipt of the managed-logs notification that logs need to be transferred. (Event 400)
  • managedlogswarn: Specify this option to test receipt of the managed-logs notification that logs are nearly full and must be transferred to avoid losing older entries. (Event 401)
  • managedlogswrap: Specify this option to test receipt of the managed-logs notification that logs have wrapped and older entries may be lost. (Event 402)
  • notification: Specify this option to test receipt of event-notification messages by every interface that is configured to receive them, such as email, SNMP, and SMI-S. (Event 312)
  • snmp: This option behaves the same as the notification option.
region crash1|crash2|crash3|crash4|ecdebug|mc|scdebug
Optional. For use with the managed logs feature, this parameter specifies the log type (debug-data region) for which to send notifications.
  • crash1, crash2, crash3, or crash4: Specify one of these options to send notification for one of the Storage Controller’s four crash logs.
  • ecdebug: Specify this option to send notification for the Expander Controller log.
  • mc: Specify this option to send notification for the Management Controller log.
  • scdebug: Specify this option to send notification for the Storage Controller log, which includes the event log.

If this parameter is omitted, the command sends four representative log types: crash1, ecdebug, scdebug, and mc.

Examples Test receipt of event notifications by every interface that is configured to receive them.

# test notification

Test receipt of the managed-logs notification that the Storage Controller log needs to be transferred.

# test managedlogs region scdebug

See also

set email-parameters

set ntp-parameters


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\