Dell EMC SmartFabric OS10 User Guide Release 10.5.0

MX7000 Feb 2020 Solution Update Instructions

Following MX7000 components have new versions:

Table 1. MX7000 ComponentsMX7000 Components
Component Version
iDRAC with Lifecycle Controller 4.11.11.11
Dell EMC Server BIOS PowerEdge MX740c 2.5.4
Dell EMC Server BIOS PowerEdge MX840c 2.5.4
Qlogic 26XX series Fibre Channel adapters 15.05.12
Qlogic 27XX series Fibre Channel adapters 15.05.12
Qlogic 41xxx series adapters 15.05.14
Mellanox ConnectX-4 Lx Ethernet Adapter Firmware 14.25.80.00
Intel NIC Family Version 19.5.x Firmware for X710, XXV710, and XL710 adapters 19.5.12
Emulex Fibre Channel Adapter Firmware 03.02.18
OpenManage Enterprise Modular 1.10.20
MX9116n Fabric Switching Engine OS10 10.5.0.5
MX5108n Ethernet Switch OS10 10.5.0.5
NOTE As these update instructions include updates to various components of the solution, there is a possibility of traffic impact to existing workloads. It is highly recommended to apply the updates only during a regular maintenance.
NOTE After updating all applicable solution components, it is recommended to reboot compute hosts.

Update Order Instructions:

Before proceeding with the update, review and resolve any recurring port alerts reported in the OME Modular Alerts page.

  • Message Id for port "operational" and "not operational" is NINT0001 and NINT0002.
NINT0001 and NINT0002
  1. Update component " iDRAC with Lifecycle Controller " via OME Modular.
    1. If OME Modular is managing a "Chassis Group", then login to OME Modular of the Lead chassis.
    2. From the global menu, click Devices and select Compute from the dropdown.
    3. This lists all the available Compute devices in the chassis or chassis group.
    4. Select the checkbox to select all the Compute devices in the current page. If there are multiple pages, then navigate to each page and select the checkbox.
    5. Once all the Compute devices in all the pages are selected, click "Update Firmware" menu button.
    6. In the popup wizard, select the individual package and click Browse button to select the " iDRAC with Lifecycle Controller " DUP.
    7. Once the DUP is uploaded, click Next and select the Compliance checkbox. Click Finish to start the update on all the Compute devices.
    8. Allow the job to complete before proceeding to Step 2.
  2. Repeat Step 1 instructions to update components " Dell EMC Server BIOS PowerEdge MX740c " and " Dell EMC Server BIOS PowerEdge MX840c" as applicable.

  3. Repeat Step 1 instructions to update components " Qlogic 26XX series Fibre Channel adapters ", "Qlogic 27XX series Fibre Channel adapters", "Qlogic 41xxx series adapters", "Mellanox ConnectX-4 Lx Ethernet Adapter Firmware", "Intel NIC Family Version 19.5.x Firmware for X710, XXV710 and XL710 adapters", and "Emulex Picard-16/Picard-32 adapters" as applicable. It is recommended to visit Dell.com to download the latest device drivers associated with firmware update.

  4. Update component "OpenManage Enterprise Modular" .

    1. If OME Modular is managing a "Chassis Group", then login to OME Modular of the Lead chassis.
    2. If the current version is either 1.10.00 or 1.10.10, skip to Step 4d.

    3. If the current version is 1.00.01 or 1.00.10, an update to the bridge version 1.10.00 or 1.10.10 is required before updating to 10.10.20. Follow the steps to update to 1.10.10.
      NOTE Updating to 1.1.x may log alert HWC7522 and require MX7116n or PTM IOMs to be rebooted.
      .
      1. From the global menu, click Devices and select Chassis from the dropdown.
      2. This list all the Chassis devices.
      3. Select the checkbox to select all the Chassis in the current page. If there are multiple pages, then navigate to each page and select the checkbox.
      4. Once all the Chassis devices in all the pages are selected, click "Update Firmware" menu button.
      5. In the popup wizard, select the individual package and click Browse button to select the "OpenManage Enterprise Modular" 1.10.10 DUP.

      6. Once the DUP is uploaded, click Next and select the top Compliance checkbox. Click Finish to start the update on all Chassis.
      7. Allow the job to complete.
    4. Current version is either 1.10.00 or 1.10.10 .

      1. From the global menu, click Devices and select Chassis from the dropdown.
      2. This list all Chassis devices.
      3. Select the checkbox to select all the Chassis on the current page. If there are multiple pages, then navigate to each page and select the checkbox.
      4. Once all the Chassis devices in all the pages are selected, click "Update Firmware" menu button.
      5. In the popup wizard, select the individual package and click Browse button to select the "OpenManage Enterprise Modular" 1.10.20 DUP.

      6. Once the DUP is uploaded, click Next and select the Compliance checkbox. Click Finish to start the update on all Chassis.
      7. Allow the job to complete.
  5. Update the "Fabric Switching Engine" and "Ethernet Switch" components.

    1. Collect the following information required to execute the updates.
      1. Identify and note the Switch SERVICE-TAG and its ROLE in the smart fabric cluster by executing the "show smartfabric cluster" command in the Switch CLI. This command is executed on all the switches in single or multi chassis group.

        Sample output from a Chassis-group Member:
        MX9116N-A1# show smartfabric cluster
        
        ----------------------------------------------------------
        CLUSTER DOMAIN ID : 159
        VIP               : fde1:53ba:e9a0:de14:0:5eff:fe00:1159
        ROLE              : BACKUP
        SERVICE-TAG       : MXWV011
        MASTER-IPV4       : 100.69.101.170
        PREFERRED-MASTER  :
        ----------------------------------------------------------
        MX9116N-A1#
        
        
        Sample output from a Chassis-group Master:
        MX9116N-A2# show smartfabric cluster
        
        ----------------------------------------------------------
        CLUSTER DOMAIN ID : 159
        VIP               : fde1:53ba:e9a0:de14:0:5eff:fe00:1159
        ROLE              : MASTER
        SERVICE-TAG       : MXWV122
        MASTER-IPV4       : 100.69.101.170
        PREFERRED-MASTER  :
        ----------------------------------------------------------
        MX9116N-A2#
        
        
      2. On the networking switch with the ROLE as MASTER, run the "show smartfabric cluster member" command to get the details of all the discovered switches in the OME Modular Chassis group. This command output provides a reference for the upgrade procedure.
        MX9116N-A2# show smartfabric cluster member
        Service-tag    IP Address                                 Status    Role    Type     Chassis-Service-Tag   Chassis-Slot
        --------------------------------------------------------------------------------------------------------------------------
        MXWV122        fde1:53ba:e9a0:de14:2204:fff:fe20:56c9     ONLINE    MASTER  MX9116n  SKYMX02               A2
        MXLE103        fde1:53ba:e9a0:de14:2204:fff:fe21:cac9     ONLINE    BACKUP  MX9116n  SKYMX10               B2
        MXLE093        fde1:53ba:e9a0:de14:2204:fff:fe21:7fc9     ONLINE    BACKUP  MX9116n  SKYMX10               B1
        MXWV011        fde1:53ba:e9a0:de14:2204:fff:fe21:9f49     ONLINE    BACKUP  MX9116n  SKYMX02               A1
        MX9116N-A2#
        
        
      3. It is highly recommended to upgrade all the networking switches (MX9116n and MX5108n) in the MSM Chassis group to 10.5.0.5. During the upgrade process, it is not recommended to make any configuration changes in the chassis-group.
      4. For upgrading the networking switch from 10.4.0E (R3S or R4S), refer to the Upgrade and Downgrade section in the existing SmartFabric Release Notes for additional instructions.
      5. For upgrading the networking switches from 10.5.0.x to 10.5.0.5, it is recommended to upgrade via CLI, detailed in the "Networking Switch CLI upgrade procedure" section.

      6. Power cycle the MX7000 chassis after updating all applicable solution components.
    2. Networking I/O Module CLI Upgrade Procedure
      1. The master Networking I/O Module should be upgraded only after all the members in the chassis-group have completed the upgrade.
      2. If the chassis-group has a mix of MX5108n and MX9116n, complete the upgrade of the MX5108n Networking I/O Modules first (non-Master) and then upgrade the MX9116n Networking I/O Modules.
      3. If multiple Networking I/O Modules are to be upgraded, ensure not more than two Networking I/O Modules are upgraded concurrently (and each Networking I/O Module needs to be part of different fabrics).
      4. Perform the following steps to upgrade the Networking I/O Module:
        1. (Optional) Backup the current running configuration to the startup configuration in EXEC mode.
          Table 2. Command DescriptionCommand Description
          Command Description
          OS10# copy running-configuration startup-configuration Back up the running configuration to startup configuration.
        2. Backup the startup configuration in EXEC mode.
          Table 3. Command DescriptionCommand Description
          Command Description
          OS10# copy config://startup.xml config://<backup file name> Back up the startup configuration in EXEC mode.
        3. Download the new software image from the Dell Support Site, extract the bin files from the tar file, and save the file in EXEC mode.
          Table 4. Command DescriptionCommand Description
          Command Description

          OS10# image download file-url

          For example:

          OS10# image download ftp://userid:passwd@hostip:/filepath

          Download the new software image.
          NOTE Some Windows unzip applications insert extra carriage returns (CR) or line feeds (LF) when they extract the contents of a .tar file, which may corrupt the downloaded OS10 binary image. Turn off this option if you use a Windows-based tool to untar an OS10 binary file.
        4. (Optional) View the current software download status in EXEC mode.
          Table 5. Command DescriptionCommand Description
          Command Description
          OS10# show image status View the current software download status.
        5. Install the 10.5.0.5 software image in EXEC mode.
          Table 6. Command DescriptionCommand Description
          Command Description

          OS10# image install image-url

          For example:

          OS10# image install image://filename.bin

          Install the software image.
        6. (Optional) View the status of the current software install in EXEC mode.
          Table 7. Command DescriptionCommand Description
          Command Description
          OS10# show image status View the status of the current software install.
        7. Change the next boot partition to the standby partition in EXEC mode. Use the active parameter to set the next boot partition from standby to active.
          Table 8. Command DescriptionCommand Description
          Command Description
          OS10# boot system standby Change the next boot partition to standby.
        8. (Optional) Check if the next boot partition has changed to standby in the EXEC mode.
          Table 9. Command DescriptionCommand Description
          Command Description
          OS10# show boot detail Check whether the next boot partition has changed.
        9. Reload the new software image in the EXEC mode.
          Table 10. Command DescriptionCommand Description
          Command Description
          OS10# reload Reload the new software.
        10. After the installation is complete, enter the show version command to check if the latest version of the software is running in the system. The example below shows that the 10.5.0.5 software is installed and running on the system.
          Table 11. Command DescriptionCommand Description
          Command Description
          OS10# show version
          MX9116N-A2# show version
          Dell EMC Networking OS10 Enterprise
          Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved.
          OS Version: 10.5.0.5
          Build Version: 10.5.0.5.661
          Build Time: 2020-02-15T00:45:32+0000
          System Type: MX9116N-ON
          Architecture: x86_64
          Up Time: 1 day 20:37:53
          MX9116N-A2#
          
          Display the software version on the system.
        11. Run the show smartfabric cluster member command in the Master networking switch. Verify that the upgraded switch has the STATUS as ONLINE in the command output after reloading.
          Table 12. Command DescriptionCommand Description
          Command Description
          MX9116N-A2# show smartfabric cluster member
          Service-tag    IP Address                                 Status    Role    Type     Chassis-Service-Tag   Chassis-Slot
          --------------------------------------------------------------------------------------------------------------------------
          MXWV122        fde1:53ba:e9a0:de14:2204:fff:fe20:56c9     ONLINE    MASTER  MX9116n  SKYMX02               A2
          MXLE103        fde1:53ba:e9a0:de14:2204:fff:fe21:cac9     ONLINE    BACKUP  MX9116n  SKYMX10               B2
          MXLE093        fde1:53ba:e9a0:de14:2204:fff:fe21:7fc9     ONLINE    BACKUP  MX9116n  SKYMX10               B1
          MXWV011        fde1:53ba:e9a0:de14:2204:fff:fe21:9f49     ONLINE    BACKUP  MX9116n  SKYMX02               A1
          MX9116N-A2#
          
          
          Display the status of the cluster members.
        12. After completing the above step, upgrade the next Networking I/O Module.
        13. After all Fabric Switching Engines are updated, all solution components (compute, chassis, and fabric switching engine) in this entire process will be updated. Power cycle the MX7000 chassis after updating all applicable solution components.