Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge T360 Installation and Service Manual

Installing the BOSS-N1 card carrier

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions .
  2. Follow the procedure that is listed in .Before working inside your system
  3. If installed, remove the front bezel.

Steps

  1. Press the release clip and pull the BOSS-N1 card carrier blank out of the system.
    Figure 1. Removing the BOSS-N1 card carrier blank
    This image shows the removal of the BOSS-N1 card carrier blank.
  2. Align the M.2 NVMe SSD at an angle with the BOSS-N1 card carrier.
  3. Insert the M.2 NVMe SSD until it is firmly seated in the BOSS-N1 card carrier.
  4. Using the Phillips 1 screwdriver, secure the M.2 NVMe SSD on the BOSS-N1 card carrier with the M3 x 0.5 x 4.5 mm screw.
    Figure 2. Installing the M.2 NVMe SSD
    Installing the M.2 NVMe SSD
  5. Align and push the BOSS-N1 card carrier into the slot in the BOSS-N1 module.
  6. Close the release latch to secure the BOSS-N1 card carrier.
    Figure 3. Installing the BOSS-N1 card carrier
    This image shows the installation of the BOSS-N1 card carrier.

Next steps

  1. If removed, install the front bezel.
  2. Follow the procedure that is listed in After working inside your system.