Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guide
Auto replacement of a virtual disk member and revertible hot spares
The automatic
Replace Member functionality allows a previously commissioned hot
spare to be reverted to a usable hot spare. When a disk failure occurs
within a virtual disk, an assigned hot spare (dedicated or global)
is commissioned and begins rebuilding until the virtual disk is optimal.
After the failed physical disk is replaced (in the same slot) and
the rebuild is complete, the Shared PERC 8 card automatically starts
to copy data from the commissioned hot spare to the newly-inserted
disk. After the data is copied, the new disk is a part of the virtual
disk and the hot spare is reverted to a ready hot spare. This allows
hot spares to remain in specific enclosure slots. While the Shared
PERC 8 card is reverting the hot spare, the virtual disk remains optimal.