SMART Error Detected On A Physical Disk In A Redundant Virtual Disk

Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Physically remove the physical disk that detected the SMART error.
    • NOTE: If a hot spare is present, the rebuild starts with the hot spare after the disk is removed.
  3. Replace the disk with a new physical disk of equal or higher capacity.
  4. Perform the Auto Replacement of a Virtual Disk operation.