Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guide

PDF

Prerequisites for removing the Shared PERC 8 card

  • CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the system.
Perform the following steps to enable recovery in the event the part replacement process fails:
  1. Follow the operating system procedure to back up all data from the shared storage drives
    • CAUTION: The part replacement procedure is complex and can put your data at risk if mistakes are made. It is imperative that critical data is backed up prior to starting the procedure.
  2. Document your virtual drive configuration and mapping information by performing the following steps:
    1. Open CLI terminal and run the command racadm raid get vdisks –o. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
    2. Click Chassis OverviewStorageVirtual DisksAssign to view the virtual disk mapping by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
    3. Click Chassis OverviewStorageVirtual Disks to get the virtual disk configuration information by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
  3. Click Chassis OverviewStorageControllers to view the firmware version of the current Shared PERC 8 card. If your system has two Shared PERC 8 cards installed, the firmware version must be the same for both the cards.
  4. Turn off the server modules using operating system commands or the CMC.
  5. Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outlet and peripherals.
  6. Remove the server modules and the shared storage hard drives from the PowerEdge VRTX system.
    • WARNING: To prevent damage to system components, do not stack system components together after removal. For information on electrostatic discharge (ESD) compliance, see dell.com/regulatory_compliance.
    • NOTE: Label all server modules and hard drives before removal so that they can be replaced in the same slots.
  7. If applicable, rotate the system feet inward and lay the system on its side on a flat stable surface, with the cover release latch side on top.
  8. Open the system.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\