Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guide
Multipath and clustering setup in VMware
Multipath Settings—No recommended settings beyond the default settings
Cluster Settings:
In VMware, LUN contention can be an issue with large cluster deployments. Below are some guidelines and settings Dell recommends you use when configuring a cluster with shared storage:
- If possible have more than 1 LUN for data storage to reduce LUN contention and reservation conflicts.
- High numbers of VMs per LUN can also increase LUN contention. Due to varying workloads it is difficult to identify precise guidelines for VMs per LUN, but it is good practice not to exceed 64 virtual machines per LUN for proper optimization of your particular solution.
- The following values are recommended for Lun Queue
Depth Throttling:
For more information, see VMware Knowledgebase article, “Controlling LUN queue depth throttling in VMware ESX/ESXi” (1008113).
queuefullsamplesize: 32 queuefullthresholdesize: 8Consult VMware documentation for more details on these settings and how to modify them. - Setting the Maximum Outstanding Disk Requests for
virtual machines:
Dell recommends the following value for Maximum Outstanding Disk Requests From Competing Worlds:For more information, see VMware Knowledgebase article, “Setting the Maximum Outstanding Disk Requests for virtual machines” (1268).
NoOfOutstandingIOsWithCompetingWorlds: 128Consult VMware documentation for more details on this setting and how to modify it. - DiskReservationThreshold:
- VMWare defines this value as the “time window within
which refcounted reservations on a device are permitted (in msec).”
This setting can be used to increase the fairness of LUN reservations
from multiple hosts. This setting can be found in the VSphere GUI.
Dell recommends the following Disk Reservation Threshold:
DiskReservationThreshold 1
- VMWare defines this value as the “time window within
which refcounted reservations on a device are permitted (in msec).”
This setting can be used to increase the fairness of LUN reservations
from multiple hosts. This setting can be found in the VSphere GUI.
- To help determine if you are getting reservation
conflicts and to get additional logging to diagnose storage contention
issues, the following log settings can be helpful:
ReservationBacktrace: 1 Scsi.LogScsiAborts: 1 Scsi.LogCmdErrors: 1