Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

chassisaction

Table 1. ChassisactionThe following table contains description, inputs, and options available in the chassisaction command.

Description

Runs a power action on the chassis or a switch.

To use this subcommand, you must have the Chassis Control Administrator privilege.

NOTE For remote racadm, check the power status of the module using the getmodinfo command.

Synopsis

racadm chassisaction [-m <module>] <action>

Input

  • -m <module> — Module on which you want to carry out the action. Values are:
    • chassis — this is the default value, if -m is not specified.
    • switch-n, where n=1
  • <action> — Action that you want to run on the specified module. Values are:
    • powerdown — (Chassis only) Turns off the chassis.
    • powerup — (Chassis only) Turns on the chassis.
    • powercycle — Power cycles the module.
    • nongraceshutdown — (Chassis only) Non-gracefully turns off the chassis.
    • reset — Performs a hard reset of the module.

When <module> = switch, <action> must be powercycle or reset.

Output

None

Example

Perform a reset of switch-1:

racadm chassisaction -m switch-1 reset
Module power operation successful.

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"