Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

racdump

Description

This subcommand displays the comprehensive chassis status and configuration state information, and historic event logs. Used for post-deployment configuration verification and during debugging sessions.

To use this subcommand for CMC, you must have the Administrator privilege.

Synopsis

racadm racdump

Input

Racdump includes the following subsystems and aggregates the following RACADM commands:

  • General System/RAC information - getsysinfo
  • Session information - getssinfo
  • Sensor information - getsensorinfo
  • Switches information (IO Module) - getioinfo
  • Mezzanine card information (Daughter card) - getdcinfo
  • All modules information - getmodinfo
  • Power budget information - getpbinfo
  • KVM information - getkvminfo
  • NIC information (CMC module) - getniccfg
  • Redundancy information - getredundancymode
  • Trace log information - gettracelog
  • RAC event log - getraclog
  • System event log - getsel

Output

The following information is displayed when the racdumpsubcommand is processed:

  • General system/RAC information
  • Coredump
  • Session information
  • Process information
  • Firmware build information
Example
racadm racdump
===============================================================================
 General System/RAC Information
===============================================================================

CMC Information:
CMC Date/Time           = Wed, 28 Nov 2007 11:55:49 PM
CMC Version             = X08
Last Firmware Update    = Wed Nov 21 21:37:56 2007
Hardware Version        = 2
Current IP Address      = 192.168.155.10
Current IP Gateway      = 192.168.155.1
Current IP Netmask      = 255.255.255.128
DHCP Enabled            = 1
MAC Address             = 00:55:AB:39:10:0F
Current DNS Server 1    = 0.0.0.0
Current DNS Server 2    = 0.0.0.0
DNS Servers from DHCP   = 0
Register DNS CMC Name   = 0
DNS CMC Name            = cmc-servicetag
Current DNS Domain      =


Chassis Information:
System Model            = PowerEdge VRTX
System AssetTag         = 00000
Service Tag             =
Chassis Name            = Dell Rack System
Chassis Location        = [UNDEFINED]
Power Status            = ON

===============================================================================
 Session Information
===============================================================================

Type    User     IP Address      Login Date/Time
SSH     root     192.168.155.10     11/28/2007 23:40:53
KVM     root     169.254.31.30   11/28/2007 18:44:51


===============================================================================
 Sensor Information
===============================================================================

<senType> <Num> <sensorName> <status> <reading> <units> <lc>
<uc>
FanSpeed    1    Fan-1         OK      14495    rpm     7250 14500
FanSpeed    2    Fan-2         OK      14505    rpm     7250 14500
FanSpeed    3    Fan-3         OK       4839    rpm     2344 14500
FanSpeed    4    Fan-4         OK      14527    rpm     7250 14500
FanSpeed    5    Fan-5         OK      14505    rpm     7250 14500
FanSpeed    6    Fan-6         OK       4835    rpm     2344 14500
FanSpeed    7    Fan-7         OK      14521    rpm     7250 14500
FanSpeed    8    Fan-8       Not OK        1    rpm     7250 14500
FanSpeed    9    Fan-9         OK       4826    rpm     2344 14500

<senType> <Num> <sensorName> <status> <reading> <units> <lc>
<uc>
Temp        1   Ambient_Temp    OK       21     celcius  N/A  40

<senType> <Num>  <sensorName>  <status>   <AC-OK status>
PWR         1       PS-1        Online          OK
PWR         2       PS-2        Online          OK
PWR         3       PS-3        Online          OK
PWR         4       PS-4       Slot Empty       N/A
PWR         5       PS-5        Failed          OK
PWR         6       PS-6        Slot Empty      N/A 

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"