Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

get enclosure

Description

Displays the status and attributes of the enclosure.
NOTE To use this subcommand, you must have the CMC Login User privilege.

Synopsis

racadm raid get enclosures -o -p Status
racadm raid get enclosures -o

Input

  • -o — The -o is used to display the fault-tolerant status of a enclosure.
  • -p — The network password of the share.

Example

racadm raid get enclosures -o -p Status
Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
Status = Ok
Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Failed
racadm raid get enclosures -o
Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
 Status                           = Ok
   RollupStatus                   = Ok
   Name                           = VRTX2.5x25 0:0
   BayId                          = 0
   FirmwareVersion                = 2.00
   AssetTag                       = elan3
   AssetName                      = VRTX200   ternal backplane
   SasAddress                     = Not applicable
   SlotCount                      = 25
Enclosure.External.0-1:RAID.ChassisSlot.5-1
   Status                           = Ok
   RollupStatus                     = Ok
   Name                             = MD1220 0:1
   EnclosurePosition                = 1
   ConnectedPort                    = 0
   FirmwareVersion                  = 1.05
   ServiceTag                       = 6Q2XMQ1
   AssetTag                         = slot 5 1
   AssetName                        = MD1220
   RedundantPath                    = Present
   SasAddress                       = Not applicable
   SlotCount                        = 24
Enclosure.External.0-0:RAID.ChassisSlot.5-1
   Status                           = Failed
   RollupStatus                     = Failed
   Name                             = MD1220 0:0
   EnclosurePosition                = 0
   ConnectedPort                    = 0
   FirmwareVersion                  = 1.05
   ServiceTag                       = BWQPWP1
   AssetTag                         = slot 5 0
   AssetName                        = MD1220
   RedundantPath                    = Present
   SasAddress                       = Not applicable
   SlotCount                        = 24

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"