Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

getsysinfo

Description
Displays information related to CMC and chassis.
NOTE The Hostname and OS Name fields in the getsysinfo output display accurate information only if Dell OpenManage Server Administrator is installed on the managed system. Else, these fields may be blank or inaccurate. An exception to this are VMware operating system names, which are displayed even if Server Administrator is not installed on the managed system.
Synopsis
racadm getsysinfo [-d] [-c] [-A] [-4] [-6]
Input
  • -d - Displays CMC information.
  • -c - Displays chassis information.
  • -A - Does not display headers and labels.
  • -4 - Displays IPv4 information.
  • -6 - Displays IPv6 information.
Output
CMC Information:
CMC Date/Time             = Sat Mar 27 1982 11:36
Primary CMC Location      = CMC-1
Primary CMC Version       = 1.00
Standby CMC Version       = N/A
Last Firmware Update      = Sun Mar 21 1982 05:53
Hardware Version          = X12

CMC Network Information:
NIC Enabled               = 1
MAC Address               = 78:45:C4:F7:8B:29
Register DNS CMC Name     = 1
DNS CMC Name              = cmc-servicetag
Current DNS Domain        = swtest.com
VLAN ID                   = 1
VLAN Priority             = 0
VLAN Enabled              = 0

CMC IPv4 Information:
IPv4 Enabled              = 1
Current IP Address        = 192.168.0.1
Current IP Gateway        = 192.168.0.1
Current IP Netmask        = 255.255.255.128
DHCP Enabled              = 1
Current DNS Server 1      = 192.168.0.1
Current DNS Server 2      = 0.0.0.0
DNS Servers from DHCP     = 1

CMC IPv6 Information:
IPv6 Enabled              = 0
Autoconfiguration Enabled = 1
Link Local Address        = ::
Current IPv6 Address 1    = ::
Current IPv6 Gateway      = ::
Current IPv6 DNS Server 1 = ::
Current IPv6 DNS Server 2 = ::
DNS Servers from DHCPv6   = 1

Chassis Information:
System Model              = PowerEdge VRTX
System AssetTag           = 00000
Service Tag               =
Express Service Code      =
Chassis Name              = CMC-
Chassis Location          = [UNDEFINED]
Chassis Midplane Version  = 1.0
Power Status              = ON
System ID                 = 1487
Examples
racadm getsysinfo -d
racadm getsysinfo -c
racadm getsysinfo -A
racadm getsysinfo -4
racadm getsysinfo -6

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"