Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

get emms

Description

Displays the status and attributes of the Enclosure Management Module (EMM).
NOTE To use this subcommand, you must have the CMC Login User privilege.

Synopsis

racadm raid get emms -o -p Status
racadm raid get emms -o

Input

  • -o — The -o is used to display the fault-tolerant status of a enclosure.
  • -p — The network password of the share.

Example

racadm raid get emms -o -p Status
Expander.Slot.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
   Status                           = Ok
Expander.Slot.1:Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
   Status                           = Ok
EMM.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
   Status                           = Ok
EMM.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
   Status                           = Ok
EMM.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
   Status                           = Failed
EMM.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
   Status                           = Unknown
racadm raid get emms -o
Expander.Slot.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
   Status                           = Ok
   State                            = Ready
   Name                             = Expander 0
   PartNumber                       = 0TJ2VKA00
   FirmwareVersion                  = 2.00
Expander.Slot.1:Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
   Status                           = Ok
   State                            = Ready
   Name                             = Expander 1
   PartNumber                       = 0TJ2VKA00
   FirmwareVersion                  = 2.00
EMM.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
   Status                           = Ok
   State                            = Ready
   Name                             = EMM 0
   PartNumber                       = 0W307KA00
   FirmwareVersion                  = 1.05
EMM.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
   Status                           = Ok
   State                            = Ready
   Name                             = EMM 1
   PartNumber                       = 0W307KA00
   FirmwareVersion                  = 1.05
EMM.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
   Status                           = Failed
   State                            = Failed
   Name                             = EMM 0
   PartNumber                       = 0W307KA00
   FirmwareVersion                  = 1.05
EMM.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
   Status                           = Unknown
   State                            = Unknown
   Name                             = EMM 1
   PartNumber                       = 0W307KA00
   FirmwareVersion                  = 1.05

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"