Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

raid

Description Monitors, retrieves inventory, and configures the storage components connected to the chassis.
NOTE To use this subcommand, you must have the Chassis Administrator privilege.
Synopsis
racadm raid get status
racadm raid get <Object type>
racadm raid get <Object type> -o
racadm raid get <Object type> -o -p <property names separated by comma>
racadm raid get <Object type>:<FQDD's of Object type separated by comma>
racadm raid set <Set Operation>:<FQDD of Object type>
racadm raid set <Set Operation> -pdkey:<FQDD of PD>
racadm raid set <Set Operation> -vdkey:<FQDD of VD>
Input
NOTE
  • Maximum property names that can be specified in –p option is 10.
  • Maximum FQDDs that can be specified is 3.
  • (Object type) — controllers, vdisks, pdisks.
  • Set Operation
    • resetconfig
    • exportlog
    • forceonline
    • deletevd
    • blink
    • unblink
    • clearconfig
    • importconfig
    • ccheck
    • cancelcheck
    • patrolread
    • hotspare
    • init
    • assignva
    • createvd
  • –o — Displays all the properties of the selected Key or Object.
  • –p — Displays the property names with filter.
  • FQDD — Displays all the properties of the FQDD's Key.
Example
  • racadm raid get controllers
  • racadm raid get controllers -o
  • racadm raid get controllers -o -p name,status
  • racadm raid get vdisks -o -p layout,status
  • racadm raid get controllers:RAID.ChassisIntegrated.1-1
  • racadm raid get controllers:RAID.ChassisIntegrated.1-1 -p status
  • racadm raid resetconfig:RAID.ChassisIntegrated.1-1
  • racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l <CIFS or NFS share> -u <user name> -p <password> [-f <filename>]
  • racadm raid forceonline:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
  • racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
  • racadm raid blink:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
  • racadm raid clearconfig:RAID.ChassisIntegrated.1-1
  • racadm raid importconfig:RAID.ChassisIntegrated.1-1
  • racadm raid ccheck:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
  • racadm raid cancelcheck:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 {-pdkey:<comma separated PD FQDDs> | {-vdkey:<comma separated VD FQDDs>}
  • racadm raid ccheckall:RAID.ChassisIntegrated.1-1
  • racadm raid cancelcheckall:RAID.ChassisIntegrated.1-1
  • racadm raid unblink {-pdkey:<comma separated PD FQDDs> | -vdkey:<comma separated VD FQDDs>}
  • racadm raid patrolread:RAID.ChassisIntegrated.1-1 [-mode {auto | manual | disabled}] [-state {start | stop}] racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1 -assign {yes | no} -type { ghs | dhs} -vdkey:<FQDD of VD>
  • racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed { fast | full } racadm raid cancelinit:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 racadm raid assignva:<VA FQDD> -vdkey:<FQDD of VD> -accesspolicy { na | rw }
  • racadm raid cancelinit:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
  • racadm raid assignva:<VA FQDD> -vdkey:<FQDD of VD> -accesspolicy { na | rw } -assignpolicy {single|multiple}
  • racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl {r0|r1|r5|r6|r10|r50|r60} [-wp {wt|wb|fwb}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}] -pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD size>{b|k|m|g|t}] [-cc] [-sc {span count}] {-current|-pending} [-vdinit {yes|no}] [-secure {yes|no}]
  • [-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD size> {b|k|m|g|t}] [-cc]
  • racadm raid discardcache:RAID.ChassisIntegrated.1-1
  • racadm raid changepolicy:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -wp {wt|wb} -rp {nra|ra|ara} -dcp {enabled|disabled|default} racadm raid rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD name>
  • racadm raid rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD name>
  • racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild <value>>] [-bgi <value>] [-reconstruct <value>] [-checkconsistency <value>] [-ccmode {abortonerror | normal}] [-copybackmode {off | on | onwithsmart}] [-lb {auto | disabled}] [-prunconfigured {yes | no}]
  • racadm raid rebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
  • racadm raid cancelrebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
  • racadm raid disableperc:RAID.ChassisIntegrated.2-1
  • racadm raid enableperc:RAID.ChassisIntegrated.2-1
  • racadm raid createsecuritykey:RAID.ChassisIntegrated.1-1 -key <Key id> -passwd <passphrase>
  • racadm raid modifysecuritykey:RAID.ChassisIntegrated.1-1 -key <Key id> -oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
  • racadm raid deletesecuritykey:RAID.ChassisIntegrated.1-1
  • racadm raid encryptvd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
  • racadm raid cryptographicerase:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
  • racadm raid unlock:RAID.ChassisIntegrated.1-1 -key <Key id> -passwd <passphrase>

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"