Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

getniccfg

Table 1. getniccfgThe following table contains the description, synopsis, and input of the getniccfg command.

Description

Displays the current NIC settings.

Synopsis

racadm getniccfg

Input

racadm getniccfg
racadm getniccfg –m <module>

where –m must be one of the following values:

  • chassis  
    : default state if -m is not specified
  •  server-n 
    : where n = 1 to 4
  • switch-n 
    : where n = 1

Example

racadm getniccfg
NIC Enabled               = 1
IPv4 Enabled              = 1
DHCP Enabled              = 1
Static IP Address         = 192.168.0.120
Static Subnet Mask        = 255.255.255.0
Static Gateway            = 192.168.0.1
Current IP Address        = 10.94.225.212
Current Subnet Mask       = 255.255.255.128
Current Gateway           = 10.94.225.129
IPv6 Enabled              = 0
Autoconfiguration Enabled = 1
Static IPv6 Address       = ::/64
Static IPv6 Gateway       = ::
Link Local Address        = ::
Current IPv6 Address 1    = ::
Current IPv6 Gateway      = ::
Speed                     = Autonegotiate
Duplex                    = Autonegotiate
VLAN Enable               = 0
VLAN ID                   = 1
VLAN priority             = 0
racadm getniccfg -m server-3
LOM Model Name            = BRCM GbE 4P 5720 bNDC
LOM Fabric Type           = Gigabit Ethernet
IPv4 Enabled              = 1
DHCP Enabled              = 0
IP Address                = 0.0.0.0
Subnet Mask               = 0.0.0.0
Gateway                   = 0.0.0.0
IPv6 Enabled              = 0
Autoconfiguration Enabled = 1
Link local Address        =
IPv6 Gateway              = ::
VLAN Enable               = 0
VLAN ID                   = 1
VLAN priority             = 0
racadm getniccfg -m switch-1
DHCP Enabled              = 0
IP Address                = 0.0.0.0
Subnet Mask               = 0.0.0.0
Gateway                   = 0.0.0.0

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"