Dell Command Monitor Error in Event Viewer: Event ID 1054 (AlertTemperatureProbeFailure)
Summary: Computer may see errors in the Windows 10 Event Viewer. The errors are related to instance ID 1054 (AlertTemperatureProbeFailure) and Dell Command | Monitor.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Affected Products:
- Dell Command | Monitor
Affected Platforms:
- OptiPlex All-In-One Plus 7410
- OptiPlex 7490 All-In-One
- Latitude 5521
- Precision 5560
- Precision 3561
Errors include:
"Temperature sensor detected a failure value Sensor location: SKIN ," "Temperature sensor detected a failure value Sensor location: VIDEO ," "Temperature sensor detected a failure value Sensor location: CPU ," "Temperature sensor detected a failure value Sensor location: DIMM A ,"
Cause
The issue occurs due to BIOS code UPPER_NON_CRITICAL_THRESHOLD_SUPPORTED and UPPER_CRITICAL_THRESHOLD_SUPPORTED not supported by the affected platforms.
Note: Removal of this code is required to resolve the issue.
Resolution
Downloading and installing the latest BIOS resolves the error.
BIOS Updates:
Affected Products
Dell Command | Monitor, Latitude 5521, OptiPlex All-in-One Plus 7410, OptiPlex 7490 All-In-One, Precision 3561, Precision 5560Article Properties
Article Number: 000197720
Article Type: Solution
Last Modified: 24 Apr 2025
Version: 8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.