Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

tc-flush-standard

Enable the MAC address flushing after receiving every topology change notification.

Syntax tc-flush-standard

To disable, use the no tc-flush-standard command.

Defaults Disabled.
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information By default, the sytem implements an optimized flush mechanism for MSTP. This mechanism helps in flushing the MAC addresses only when necessary (and less often) allowing for faster convergence during topology changes. However, if a standards-based flush mechanism is needed, this knob command can be turned on to enable flushing MAC addresses after receiving every topology change notification.