Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Configured disks removed or not accessible error message

Error Message:
Some configured disks have been removed from your system or are no longer accessible. Check your cables and ensure all disks are present. Press any key or ’C’ to continue.
Probable Cause:
The message indicates that some configured disks were removed. If the disks were not removed, they are no longer accessible. The cables from the PERC controller to the backplane might be improperly connected.
Corrective Action:
Check the cable connections and fix issues if any. Restart the system. If there are no cable problems, press any key or <C> to continue.