Redundant virtual disk fails during reconstruction

Issue:
Multiple disks fails during a reconstruction process on a redundant virtual disk that has a hot spare.
Probable Cause:
Multiple physical disks in the virtual disk is failed or the cables are disconnected.
Corrective Action:
No action is required. The physical disk to which a reconstruction operation is targeted reverts to Ready state, and the virtual disk goes to Failed state. If there are any other virtual disks that can be supported by the capacity of the hot spare then the dedicated hot spare is converted to global hot spare, if not the hot spare will revert back to Ready state.