Smart error detected on a physical disk in a non–redundant virtual disk

Issue:
A SMART error is detected on a physical disk in a non–redundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Use Replace Member to replace the disk manually.
    NOTE:For more information about the Replace Member feature, see Configure hot spare drives.
  3. Replace the affected physical disk with a new physical disk of equal or higher capacity.
  4. Restore from the backup.