Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Drive removal and insertion in the same slot generates a foreign configuration event

Issue:
When a drive which is part of a virtual disk is removed and reinserted into the same slot the drive goes through a transient state of being foreign for a short period of time before rebuilding.
Description:
This transient state could be reported as an event in management applications as A foreign configuration was detected on RAID Controller is SL x, where x is the slot of the RAID controller.
Corrective Action:
No action is required on the foreign configuration state of the drive as it is transient and the controller handles the event automatically.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\