Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series
Drive removal and insertion in the same slot generates a foreign configuration event
- Issue:
- When a drive which is part of a virtual disk is removed and reinserted into the same slot the drive goes through a transient state of being foreign for a short period of time before rebuilding.
- Description:
- This transient state could be reported as an event in management applications as A foreign configuration was detected on RAID Controller is SL x, where x is the slot of the RAID controller.
- Corrective Action:
- No action is required on the foreign configuration state of the drive as it is transient and the controller handles the event automatically.