Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Smart error detected on a physical disk in a redundant virtual disk

Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Force the physical disk offline.
    NOTE:If a hot spare is present, the rebuild starts with the hot spare after the disk is forced offline.
  3. Replace the disk with a new physical disk of equal or higher capacity.
  4. Perform the Replace Member operation.
    NOTE:The Replace Member operation allows you to copy data from a source physical disk of a virtual disk to a target physical disk that is not a part of the virtual disk. For more information about the Replace Member feature, see the topic Configure hot spare drives.