Multiple disks are inaccessible

Issue:
Multiple disks are simultaneously inaccessible.
Probable Cause:
Multiple physical disk errors in a single array typically indicate a failure in cabling or connection and could involve the loss of data.
Corrective Action:
You can recover the virtual disk after multiple physical disks become simultaneously inaccessible. Perform the following steps to recover the virtual disk:
CAUTION:Follow the safety precautions to prevent electrostatic discharge.
  1. Turn off the system, check cable connections, and reseat physical disks.
  2. Ensure that all the disks are present in the enclosure.
  3. Turn on the system and enter the HII Configuration Utility.
  4. Import the foreign configuration.
  5. Press <F> at the prompt to import the configuration, or press <C> to enter the HII Configuration Utility and either import or clear the foreign configuration.

If the virtual disk is redundant and transitioned to Degraded state before going Offline, a rebuild operation starts automatically after the configuration is imported. If the virtual disk has gone directly to the Offline state due to a cable pull or power loss situation, the virtual disk is imported in its Optimal state without a rebuild occurring.

NOTE:You can use the HII Configuration Utility or Dell OpenManage storage management application to perform a manual rebuild of multiple physical disks.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\