Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series
Multiple disks are inaccessible
- Issue:
- Multiple disks are simultaneously inaccessible.
- Probable Cause:
- Multiple physical disk errors in a single array typically indicate a failure in cabling or connection and could involve the loss of data.
- Corrective Action:
- You can recover the virtual disk after multiple physical disks become simultaneously inaccessible. Perform the following steps to recover the virtual disk:
CAUTION:Follow the safety precautions to prevent electrostatic discharge.
- Turn off the system, check cable connections, and reseat physical disks.
- Ensure that all the disks are present in the enclosure.
- Turn on the system and enter the HII Configuration Utility.
- Import the foreign configuration.
- Press <F> at the prompt to import the configuration, or press <C> to enter the HII Configuration Utility and either import or clear the foreign configuration.
If the virtual disk is redundant and transitioned to Degraded state before going Offline, a rebuild operation starts automatically after the configuration is imported. If the virtual disk has gone directly to the Offline state due to a cable pull or power loss situation, the virtual disk is imported in its Optimal state without a rebuild occurring.
NOTE:You can use the
HII Configuration Utility or Dell OpenManage storage management application to perform a manual rebuild of multiple physical disks.