Dell PowerEdge R6525 Installation and Service Manual

Removing the rear drive module

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the air shroud.
  4. Remove the rear drives.
  5. Disconnect all the cables from the rear drive module.
  6. If installed, remove the expansion card riser 3.

Steps

  1. Using a Phillips #1 screwdriver, loosen the captive screws on the rear drive module or the liquid cooling rear drive module.
  2. Slide the rear drive module and lift it away from the system.
    Figure 1. Removing the rear drive module

    This image shows Removing the rear drive module.

    Figure 2. Removing the liquid cooling rear drive module
    This image shows the installation of the liquid cooling rear drive module